TOTAL POWER INT.
MBU100
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Load
Temperature Coefficient
Output Short Circuit
Over Line,Load & Temp.
For Vin Change 1%
Io=20% to 100%
Conditions
Min.
---
---
---
---
---
120
---
Typ.
{1.0
{1.2
100
---
---
---
{0.01
Max.
{3.0
{1.5
150
200
5
---
{0.02
Unit
%
%
%
mV P-P
mV P-P
mV rms.
%
%/]
See Model Selection Guide
0.5 Second Max.
General Specification
Parameter
Rated Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500VDC
100KHz,1V
Min.
1000
1000
---
50
Typ.
---
---
60
90
Max.
---
---
100
110
Unit
VDC
M[
pF
kHz
Input Fuse Selection Guide
5V Input Models
500mA Slow - Blow Type
12V Input Models
200mA Slow - Blow Type
24V Input Models
100mA Slow - Blow Type
Typical Applications
+
Fuse
DC Power
Source
-
+Vin
Single Output
DC / DC
Converter
-Vin
+Out
Load
-Out
Connecting Pin Patterns
(2.54 mm / 0.1 inch grids )
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-3-