Absolute Maximum Ratings
Exceeding these values can damage the module.These are not continuous operating ratings.
Parameter
Input Surge Voltage
( 1000 mS )
Internal Power Dissipation
5VDC Input Models
12VDC Input Models
24VDC Input Models
Min.
-0.7
-0.7
-0.7
---
Max.
9
18
30
450
Unit.
VDC
VDC
VDC
mW
Environmental Specifications
Parameter
Operating Temperature
Storage Temperature
Humidity
Cooling
Conditions
Min.
-25
-40
---
Typ.
---
---
---
Max.
+75
+125
95
Unit
]
]
%
Free-Air Convection
Model Selection Guide
Model
Number
Input
voltage
VDC
MBU101
MBU102
MBU103
MBU104
MBU111
MBU112
MBU113
MBU114
MBU115
MBU116
MBU117
MBU118
24
(21.6 ~ 26.4)
12
(10.8 ~ 13.2)
5
(4.5 ~ 5.5)
Output
Voltage
VDC
5
9
12
15
5
9
12
15
5
9
12
15
Output
Current
mA (Max.)
200
110
84
67
200
110
84
67
200
110
84
67
Output
Current
mA (Min.)
4
2
1.5
1
4
2
1.5
1
4
2
1.5
1
Input
Current
Max. Load
mA (Typ.)
290
260
262
258
117
107
106
105
60
54
53
53
7
13
30
Input
Current
No Load
mA (Typ.)
Load
Regulation
% (Max.)
11
8
7
6
9
5
5
4
8
5
4
4
Efficiency
% (Typ.)
69
76
77
78
71
77
79
80
70
76
79
79
Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
Input Specifications
Parameter
Input Voltage Range
Reverse Polarity Input Current
Input Filter
Model
5V Input Models
12V Input Models
24V Input Models
All Models
Min.
4.5
10.8
21.6
---
Typ.
5
12
24
---
Max.
5.5
13.2
26.4
0.3
VDC
A
Unit
Internal Capacitor
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com