欢迎访问ic37.com |
会员登录 免费注册
发布采购

MDW1041 参数 Datasheet PDF下载

MDW1041图片预览
型号: MDW1041
PDF下载: 下载PDF文件 查看货源
内容描述: 2瓦2 : 1宽输入范围DC / DC转换器单路和双路输出 [2 Watts 2 :1 Wide Input Range DC/DC Converters Single and Dual Outputs]
分类和应用: 转换器
文件页数/大小: 8 页 / 243 K
品牌: TOTAL-POWER [ TOTAL POWER INTERNATIONAL ]
 浏览型号MDW1041的Datasheet PDF文件第1页浏览型号MDW1041的Datasheet PDF文件第2页浏览型号MDW1041的Datasheet PDF文件第3页浏览型号MDW1041的Datasheet PDF文件第4页浏览型号MDW1041的Datasheet PDF文件第5页浏览型号MDW1041的Datasheet PDF文件第7页浏览型号MDW1041的Datasheet PDF文件第8页  
MDW1000 Series  
Test Configurations  
Overcurrent Protection  
To provide protection in a fault (output overload) condition,  
the unit is equipped with internal current limiting circuitry and  
can endure current limiting for an unlimited duration. At the  
point of current-limit inception, the unit shifts from voltage  
control to current control. The unit operates normally once the  
output current is brought back into its specified range.  
Input Reflected-Ripple Current Test Setup  
To Oscilloscope  
+Vin  
+Out  
+
+
Lin  
DC / DC  
Converter  
Current  
Probe  
Load  
Battery  
Cin  
-Vin  
-Out  
Input Source Impedance  
The power module should be connected to a low  
ac-impedance input source. Highly inductive source  
impedances can affect the stability of the power module.  
In applications where power is supplied over long lines and  
output loading is high, it may be necessary to use a capacitor  
on the input to insure startup.  
Input reflected-ripple current is measured with a inductor  
Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 kHz) to  
simulated source impedance.  
Capacitor Cin, offsets possible battery impedance.  
Current ripple is measured at the input terminals of the  
module, measurement bandwidth is 0-500KHz.  
By using a good quality low Equivalent Series Resistance  
(ESR < 1.0[ at 100 kHz) capacitor of a 8.2uF for the 5V input  
devices, a 3.3uF for the 12V input devices and a 1.5uF for the  
24V and 48V devices, capacitor mounted close to the power  
module helps ensure stability of the unit.  
Peak-to-Peak Output Noise Measurement Test  
Use a Cout 0.47uF ceramic capacitor.  
Scope measurement should be made by using a BNC  
socket, measurement bandwidth is 0-20 MHz. Position the  
load between 50 mm and 75 mm from the DC/DC Converter.  
+
+Vin  
DC / DC  
+Out  
-Out  
+
+Vin  
+Out  
Copper Strip  
Cout  
DC Power  
Source  
Load  
Converter  
Single Output  
DC / DC  
Cin  
Resistive  
Load  
Scope  
-
-Vin  
Converter  
-Vin  
-Out  
Output Ripple Reduction  
Copper Strip  
Cout  
+Vin  
+Out  
Com.  
-Out  
A good quality low ESR capacitor placed as close as  
practicable across the load will give the best ripple and noise  
performance.  
To reduce output ripple, it is recommended that 3.3uF  
capacitors are used on output.  
Scope  
Scope  
Dual Output  
DC / DC  
Resistive  
Load  
Converter  
Cout  
-Vin  
+
+Vin  
-Vin  
+Out  
-Out  
Single Output  
DC / DC  
Design & Feature Considerations  
Maximum Capacitive Load  
DC Power  
Source  
Converter  
Cout  
Load  
-
The MDW1000 series has limitation of maximum  
connected capacitance on the output.  
The power module may operate in current limiting mode  
during start-up, affecting the ramp-up and the startup time.  
+
+Vin  
-Vin  
+Out  
Dual Output  
Cout  
Load  
For optimum performance we recommend maximum  
1000uF capacitive load for dual outputs and 4000uF capacitive  
load for single outputs.  
DC Power  
Source  
DC / DC Com.  
Converter  
-
-Out  
Connect capacitors at the point of load for best  
performance.  
The maximum capacitance can be found in the data.