TOTAL POWER INT'L
MIW1000
Input Fuse Selection Guide
5V Input Models
1500mA Slow - Blow Type
12V Input Models
700mA Slow - Blow Type
24V Input Models
350mA Slow - Blow Type
48V Input Models
135mA Slow - Blow Type
Typical Applications
+
Fuse
DC Power
Source
-
+Vin
Single Output
DC / DC
Converter
-Vin
-Out
+Out
Load
+
Fuse
DC Power
Source
-
+Vin
Dual Output
DC / DC
Converter
-Vin
+Out
Load #1
Common
Load #2
-Out
Derating Curve
100
80
Output
Power
%
60
40
20
0
-25
-10
0
20
40
60
O
100
80
60
40
-3.3% /
O
C
20
0
80
C
100
125
Output
Power
%
Ambient Temperature
Connecting Pin Patterns
(2.54 mm / 0.1 inch grids )
Single Output
Dual Output
NOTE:
1. Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a step change in output load of 50% to 100%.
3. When measure output ripple & noise,an external 0.1uF ceramic capacitor is recommended to be placed from +Vout
to -Vout (single output) and each output to common (dual output).
4. Other input and output voltage may be available,Please contact factory.
5. Specifications subject to change without notice.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-4-