TOTAL POWER INT'L
Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
Output Current
MIW1500 Series
Input Current
Reflected
Ripple
Current
mA ( T y p . )
Efficiency
VDC
MIW1512
MIW1513
MIW1516
MIW1517
MIW1522
MIW1523
MIW1526
MIW1527
MIW1532
MIW1533
MIW1536
MIW1537
5
( 4.5 ~ 9 )
VDC
5
12
{12
{15
5
12
{12
{15
5
12
{12
{15
Max.
mA
600
250
{125
{100
600
250
{125
{100
600
250
{125
{100
Min.
mA
60
25
{12.5
{10
60
25
{12.5
{10
60
25
{12.5
{10
@Max. Load @No Load
mA ( T y p . )
mA ( T y p . )
833
789
779
779
329
313
313
313
160
152
152
152
@Max.
% Load . )
(Typ
72
76
77
77
76
80
80
80
78
82
82
82
40
100
12
( 9 ~ 18 )
20
30
24
( 18 ~ 36 )
5
15
Absolute Maximum Ratings
Parameter
5VDC Input Models
Input Surge Voltage
12VDC Input Models
( 1000 mS )
24VDC Input Models
Lead Temperature (1.5mm from case for 10
Sec.) Power Dissipation
Internal
Min.
-0.7
-0.7
-0.7
---
---
Max.
11
25
50
260
2,500
Unit
VDC
VDC
VDC
]
mW
Note :
1. Specifications typical at Ta=+25], resistive
load, nominal input voltage, rated output current
unless otherwise noted.
2. Transient recovery time is measured to within 1%
error band for a step change in output load of
75% to 100%.
3. Ripple & Noise measurement bandwidth is 0-20
MHz.
4. These power converters require a minimum
output loading to maintain specified regulation.
5. Operation at no-load will not damage these
units. However, they may not meet all
specifications.
Min.
-25
Max.
+71
Unit
]
]
]
%
6. All DC/DC converters should be externally fused
at the front end for protection.
7. Other input and output voltage may be available,
please contact factory.
8. Specifications subject to change without notice.
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conducted EMI
Conditions
Ambient
Case
-25
+90
-40
+125
---
95
Free-Air Convection
EN55022 Class A