MIW4100 Series
Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
Output Current
Input Current
Reflected
Ripple
Current
mA (Typ.)
Efficiency
VDC
MIW4121
MIW4122
MIW4123
MIW4124
MIW4125
MIW4126
MIW4127
MIW4131
MIW4132
MIW4133
MIW4134
MIW4135
MIW4136
MIW4137
48
( 18 ~ 75 )
24
( 9 ~ 36 )
VDC
3.3
5
12
15
{5
{12
{15
3.3
5
12
15
{5
{12
{15
Max.
mA
1200
1000
500
400
{500
{250
{200
1200
1000
500
400
{500
{250
{200
Min.
mA
120
100
50
40
{50
{25
{20
120
100
50
40
{50
{25
{20
@Max. Load
mA (Typ.)
220
267
301
305
267
301
305
110
134
151
152
134
151
152
@No Load
mA (Typ.)
@Max. Load
% (Typ.)
75
78
83
20
20
82
78
83
82
75
78
83
10
15
82
78
83
82
Absolute Maximum Ratings
Parameter
Input Surge Voltage
( 1000 mS )
Internal Power Dissipation
24VDC Input Models
48VDC Input Models
Min.
-0.7
-0.7
---
---
Max.
50
100
260
2,500
Unit
VDC
VDC
]
mW
Notes :
1. Specifications typical at Ta=+25], resistive load,
nominal input voltage, rated output current unless
otherwise noted.
2. Transient recovery time is measured to within 1%
error band for a step change in output load of 75%
to 100%.
3. Ripple & Noise measurement bandwidth is 0-20
MHz.
4. These power converters require a minimum output
loading to maintain specified regulation.
Lead Temperature (1.5mm from case for 10 Sec.)
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conducted EMI
Conditions
Ambient
Case
Min.
-40
-40
-40
---
Free-Air Convection
EN55022 Class A
Max.
+71
+95
+125
95
Unit
]
]
]
%
5. Operation under no-load conditions will not
damage these modules; however, they may not
meet all specifications listed.
6. All DC/DC converters should be externally fused at
the front end for protection.
7. Other input and output voltage may be available,
please contact factory.
8. Specifications subject to change without notice.