欢迎访问ic37.com |
会员登录 免费注册
发布采购

PBA100F-5 参数 Datasheet PDF下载

PBA100F-5图片预览
型号: PBA100F-5
PDF下载: 下载PDF文件 查看货源
内容描述: [PBA100F]
分类和应用:
文件页数/大小: 1 页 / 102 K
品牌: TOTAL-POWER [ TOTAL POWER INTERNATIONAL ]
   
Unit type
Ordering information
PBA100F
R
PBA 100
1
2
3
F
4
-5
5
-O
1Series name
2 Output wattage
3 Universal input
4 Output voltage
5 Optional
C :with Coating
G :Low leakage current
(0.15mA max / ACIN 240V)
E :Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T :Vertical terminal block
J :Connector type
(Only -24, -36, -48)
R :with Remote ON/OFF
N :with Cover
(Only 24V UL508 pending)
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
Specification is changed at
option. Please consult us
details.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA100F-3R3 PBA100F-5
66
100
3.3V 20A
5V 20A
PBA100F-9
94.5
9V 10.5A
PBA100F-12
102
12V 8.5A
PBA100F-15
105
15V 7A
PBA100F-24
108
24V 4.5A
PBA100F-36
100.8
36V 2.8A
PBA100F-48
100.8
48V 2.1A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
EFFICIENCY[%]
PBA100F-3R3 PBA100F-5
PBA100F-9
PBA100F-12
PBA100F-15
AC85 - 264 1f or DC120 - 370 (AC70 or DC100 optionally available *4)
ACIN 100V
0.9typ
1.3typ
ACIN 200V
0.5typ
0.7typ
50/60 (47 - 63)
ACIN 100V
77typ
81typ
ACIN 200V
79typ
84typ
PBA100F-24
PBA100F-36
PBA100F-48
80typ
82typ
81typ
83typ
83typ
86typ
84typ
86typ
84typ
86typ
84typ
86typ
OUTPUT
ACIN 100V
0.98typ
0.99typ
POWER FACTOR(Io=100%) ACIN 200V
0.87typ
0.93typ
ACIN 100V
20typ (Io=100%) (At cold start)
INRUSH CURRENT[A]
ACIN 200V
40typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA]
0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1)
VOLTAGE[V]
3.3
5
9
12
15
CURRENT[A]
20
20
10.5
8.5
7
LINE REGULATION[mV]
20max
20max
36max
48max
60max
LOAD REGULATION[mV]
40max
40max
100max
100max
120max
0 to +50C
*1
80max
80max
120max
120max
120max
RIPPLE[mVp-p]
-10 - 0C
*1
140max
140max
160max
160max
160max
0 to +50C
*1
120max
120max
150max
150max
150max
RIPPLE NOISE[mVp-p]
-10 - 0C
*1
160max
160max
180max
180max
180max
0 to +50C
50max
50max
90max
120max
150max
TEMPERATURE REGULATION[mV]
-10 to +50C
60max
60max
120max
150max
180max
DRIFT[mV]
*2
20max
20max
36max
48max
60max
START-UP TIME[ms]
350typ(ACIN 100V, Io=100%)
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.60
4.00 - 5.50
7.50 - 10.0
10.0 - 13.2
13.2 - 18.0
OUTPUT VOLTAGE SETTING[V]
3.20 - 3.40
4.90 - 5.20
8.70 - 9.30
11.5 - 12.5
14.5 - 15.5
OVERCURRENT PROTECTION
Works over 105% of rated current and recovers automatically
24
4.5
96max
150max
120max
160max
150max
180max
240max
290max
96max
36
2.8
144max
240max
150max
200max
250max
300max
360max
450max
144max
48
2.1
192max
240max
150max
200max
250max
300max
480max
600max
192max
19.2 - 27.0
23.5 - 24.5
28.8 - 39.0
35.5 - 36.5
43.0 - 50.0
39.0 - 53.0
47.0 - 49.0
58.0 - 65.0
5.75 - 7.00
11.5 - 14.0
15.0 - 18.0
20.0 - 25.0
30.0 - 37.0
PROTECTION OVERVOLTAGE PROTECTION[V]
4.00 - 5.25
CIRCUIT AND OPERATING INDICATION
LED (Green)
OTHERS
REMOTE SENSING
Optional (Only -3R3, -5 Option -K)
REMOTE ON/OFF
Optional (Required external power source)
INPUT-OUTPUT
-RC
*3
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
ISOLATION
OUTPUT-RC-FG
*3
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
,
ENVIRONMENT STORAGE TEMP. HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY AND CONDUCTED NOISE
NOISE
REGULATIONS CE MARKING
HARMONIC ATTENUATOR
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
-20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
19.6m/s
2
(2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input)
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
32X93X147mm (without terminal block) (WXHXD) / 440g max (without cover)
Convection
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
*4 Derating is required.Consult us for details.
*1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :
RM101).
*2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*
Parallel operation with other model is not possible.