TOTAL POWER INT'L
S2A00R
Absolute Maximum Ratings
Exceeding these values can damage the module.These are not continuous operating ratings.
Parameter
Input Surge Voltage
( 1000 mS )
5VDC Input Models
12VDC Input Models
24VDC Input Models
48VDC Input Models
Internal Power Dissipation
Min.
-0.7
-0.7
-0.7
-0.7
---
Max.
7.5
15
30
55
3000
Unit.
VDC
VDC
VDC
VDC
mW
Environmental Specifications
Parameter
Operating Temperature
Storage Temperature
Humidity
Cooling
Conditions
Min.
-25
-40
---
Typ.
---
---
---
Max.
+71
+125
95
Unit
]
]
%
Free-Air Convection
Model Selection Guide
Model
Number
Input
voltage
VDC
S2A01R
S2A02R
S2A03R
S2A04R
S2A05R
S2A06R
S2A07R
S2A08R
S2A09R
S2A10R
S2A11R
S2A12R
S2A13R
S2A14R
S2A15R
S2A16R
S2A17R
S2A18R
S2A19R
S2A20R
48
(43.2 ~ 52.8)
24
(21.6~26.4)
12
(10.8 ~13.2)
5
(4.5 ~ 5.5)
Output
Voltage
VDC
5
12
15
{12
{15
5
12
15
{12
{15
5
12
15
{12
{15
5
12
15
{12
{15
Output
Current
mA (Max.)
600
250
200
{125
{100
600
250
200
{125
{100
600
250
200
{125
{100
600
250
200
{125
{100
0
0
0
0
Output
Current
mA (Min.)
Input
Current
Max. Load
mA (Typ.)
1000
960
960
1000
1000
420
400
400
420
420
210
195
195
210
210
105
100
100
105
105
15
10
25
25
50
40
100
100
Input
Current
No Load
mA (Typ.)
Reflected
Ripple
Current
mA (Typ.)
Efficiency
% (Typ.)
60
62
62
60
60
60
62
62
60
60
60
64
64
60
60
60
62
62
60
60
Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-2-