TOTAL POWER INT'L
S2D00R
Absolute Maximum Ratings
Exceeding these values can damage the module.These are not continuous operating ratings.
Parameter
Input Surge Voltage
( 1000 mS )
5VDC Input Models
12VDC Input Models
24VDC Input Models
48VDC Input Models
Internal Power Dissipation
Min.
-0.7
-0.7
-0.7
-0.7
---
Max.
7.5
15
30
55
3000
Unit.
VDC
VDC
VDC
VDC
mW
Environmental Specifications
Parameter
Operating Temperature
Storage Temperature
Humidity
Cooling
Conditions
Min.
-25
-40
---
Typ.
---
---
---
Max.
+71
+125
95
Unit
]
]
%
Free-Air Convection
Model Selection Guide
Model
Number
Input
voltage
VDC
S2D01R
S2D02R
S2D03R
S2D04R
S2D05R
S2D06R
S2D07R
S2D08R
S2D09R
S2D10R
S2D11R
S2D12R
S2D13R
S2D14R
S2D15R
S2D16R
S2D17R
S2D18R
S2D19R
S2D20R
48
(43.2~52.8)
24
(21.6~26.4)
12
(10.8 ~13.2)
5
(4.75 ~ 5.25)
Output
Voltage
VDC
5
12
15
{12
{15
5
12
15
{12
{15
5
12
15
{12
{15
5
12
15
{12
{15
Output
Current
mA (Max.)
400
165
133
{83
{66
400
165
200
{83
{100
400
165
200
{83
{100
400
165
200
{83
{100
0
0
0
0
Output
Current
mA (Min.)
Input
Current
Max. Load
mA (Typ.)
666
628
633
642
639
277
262
397
268
403
138
131
198
134
202
69
66
99
67
101
15
10
25
15
50
30
100
70
Input
Current
No Load
mA (Typ.)
Reflected
Ripple
Current
mA (Typ.)
Efficiency
% (Typ.)
60
63
63
62
62
60
63
63
62
62
60
63
63
62
62
60
63
63
62
62
Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-2-