TOTAL POWER INT'L
100W Single Output with PFC Function
Features :
Universal AC input / full range
SP-100
series
Built-in active PFC function, PF>0.93
Protections:Short circuit/Over load/Over voltage
Built-in constant current limiting circuit
Remote ON-OFF control(Optional)
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
SP-100-3.3
3.3V
20A
0 ~ 20A
66W
SP-100-5
5V
20A
0 ~ 20A
100W
SP-100-7.5
7.5V
13.5A
0 ~ 13.5A
101.25W
100mVp-p
SP-100-12
12V
8.5A
0 ~ 8.5A
102W
100mVp-p
SP-100-13.5 SP-100-15
13.5V
7.5A
0 ~ 7.5A
101.25W
100mVp-p
15V
6.7A
0 ~ 6.7A
100.5W
100mVp-p
SP-100-24
24V
4.2A
0 ~ 4.2A
100.8W
150mVp-p
SP-100-27
27V
3.8A
0 ~ 3.8A
102.6W
150mVp-p
SP-100-48
48V
2.1A
0 ~ 2.1A
100.8W
250mVp-p
100mVp-p
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE ADJ. RANGE
3.14 ~ 3.63V 4.75 ~ 5.5V
2.0%
VOLTAGE TOLERANCE
Note.3
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
0.5%
1.0%
85 ~ 264VAC
47~63Hz
PF>0.93/230VAC
70%
76%
7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
2.0%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
0.5%
1.0%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
600ms, 30ms, 20ms at full load
120 ~ 370VDC
PF>0.98/115VAC at full load
78%
80%
80%
82%
84%
83%
82%
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
OVER LOAD
1.7A/115VAC
0.8A/230VAC
COLD START 40A/230VAC
<2mA / 240VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.63 ~ 4.46V 5.5 ~ 6.75V 8.25 ~ 10.13V 13.2 ~ 16.2V 14.85 ~ 18.23V 16.5 ~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.45V 52.8 ~ 64.8V
PROTECTION
OVER VOLTAGE
FUNCTION
Protection type : Shut down o/p voltage, re-power on to recover
REMOTE CONTROL(OPTION)
CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.05%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1950, TUV EN60950 Approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
211.3K hrs min. MIL-HDBK-217F (25
179*99*45mm (L*W*H)
0.6Kg; 20pcs/12Kg/1.17CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.