TOTAL POWER INT'L
40W Triple Output Switching Power Supply
Features :
Universal AC input / Full range
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 40KHz
2 years warranty
T- 4 0
series
Protections:Short circuit/Over load/Over voltage
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
T-40A
5V
3A
0.6 ~ 5A
41.5W
100mVp-p
8.0%
1.0%
6.0%
T-40B
12V
2A
0.2 ~ 3A
-5V
0.5A
0.1 ~ 1A
5V
3A
0.6 ~ 5A
45W
100mVp-p
120mVp-p
120mVp-p
8.0%
1.0%
6.0%
T-40C
12V
2A
0.2 ~ 3A
-12V
0.5A
0.1 ~ 1A
5V
3A
0.6 ~ 5A
45W
100mVp-p
2.0%
0.5%
0.5%
15V
1.5A
0.2 ~ 2A
120mVp-p
6.0%
1.0%
4.0%
-15V
0.5A
0.1 ~ 1A
120mVp-p
6.0%
1.0%
4.0%
120mVp-p
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V
6.0%
VOLTAGE TOLERANCE
Note.3
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT
INRUSH CURRENT(max.)
LEAKAGE CURRENT
OVER LOAD
0.5%
0.5%
85 ~ 264VAC
47 ~ 63Hz
72%/115VAC
CH1 : 4.75 ~ 5.5V
2.0%
6.0%
0.5%
0.5%
1.0%
4.0%
CH1 : 4.75 ~ 5.5V
1.0%
4.0%
800ms, 50ms, 60ms/230VAC
120 ~ 370VDC
1.6s, 50ms,16ms/115VAC at full load
INPUT
72%/115VAC
72%/115VAC
1.2A/115VAC
0.7A/230VAC
COLD START 20A/115VAC
40A/230VAC
<3.5mA / 240VAC
105 ~ 150%/115VAC of rate load
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60
-20 ~ +85
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
(Refer to output load derating curve)
, 10 ~ 95% RH
20 ~ 90% RH non-condensing
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
CSA 950, (UL1950, IEC950, TUV EN60950) Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A
305.6K hrs min. MIL-HDBK-217F (25
129*98*38mm (L*W*H)
0.45Kg; 30pcs/13.5Kg/0.86CUFT
)
OTHERS
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.