DC/DC Converters
TEN 3 Series
Input Specifications
Input current no load /full load
5
12
24
48
5
12
24
48
5
12
24
48
Vin
Vin
Vin
Vin
Vin
Vin
Vin
Vin
Vin
Vin
Vin
Vin
models
models
models
models
models
models
models
models
models
models
models
models
40 mA / 800 mA typ.
20 mA / 300 mA typ.
5 mA / 150 mA typ.
3 mA / 75 mA typ.
4 VDC / 3.5 VDC typ.
7 VDC / 6.5 VDC typ.
12 VDC / 11 VDC typ.
24 VDC / 22 VDC typ
11 V max.
25 V max.
50 V max.
100 V max.
1.0 A max.
(5 V input models excluded)
EN 55022 level A, FCC part 15, level A
±1%
– Input variation Vin min. to Vin max.
– Load variation 10 – 100 %
single output models
dual output models balanced load
dual output models unbalanced load
0.5 % max.
0.5 % max.
1.0 % max.
2.0 % max.
50 mVpk-pk max
± 0.02 % /K
> 110% of Iout max., constant current
indefinite, automatic recovery
single output models
4000 µF max.
dual output models
1000 µF max.
– Operating
– Case temperature
– Storage
– 40 °C ... + 85 °C
+ 100 °C max.
– 55 °C ... +125°C
3% /K above 70°C
95 % rel H max.
>1.1 Mio. h @ + 25 °C
1’500 VDC
65 pF typ
> 1‘000 M Ohm
300 kHz typ. (Pulse frequency modulation PFM)
UL 60950-1, IEC 60950-1, EN 60950-1
CSA File No. 226037
– Input/Output
– Input/Output
– Input/Output (500 VDC)
3 Watt
Start-up voltage /
under voltage shut down
Surge voltage
(1 sec. max.)
Reverse voltage protection
Conducted noise
(input)
Output Specifications
Voltage set accuracy
Regulation
Ripple and noise
(20 MHz Bandwidth)
Temperature coefficient
Current limitation
Short circuit protection
Capacitive load
General Specifications
Temperature ranges
Derating
Humidity
(non condensing)
Reliability, calculated MTBF
(MIL-HDBK-217E ground benign)
Isolation voltage
(60 sec.)
Isolation capacity
Isolation resistance
Switching frequency
Safety standards
Safety approval
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3