DC/DC Converters
TEN 5WI Series
Input Specifications
Input current no load /full load
Start-up voltage /
under voltage shut down
Surge voltage
(1 sec. max.)
Reverse voltage protection
Conducted noise
(input)
24 Vin models:
20 mA typ.
48 Vin models:
10 mA typ.
24 Vin models:
9 VDC / 8.5 VDC typ.
48 Vin models:
18 VDC / 16 VDC typ.
24 Vin models:
50 V max.
48 Vin models:
100 V max.
1.0 A max.
EN 55022 level A, FCC part 15, level A
± 2.0 % max.
– Input variation Vin min. to Vin max.
± 0.3 % max.
– Load variation 10 – 100 %
single output models:
± 2.0 % max.
dual output models:
± 2.0 % max.
balanced load
± 3.0 % max.
unbalanced load
75 mVpk-pk max
± 0.02 % / K
> 110% of Iout max., constant current
indefinite (automatic recovery)
3.3 /5
12 /15
±5
±12
/±15
– Operating
– Case temperature
– Storage
VDC
VDC
VDC
VDC
models
models
models
models
1000 µF max.
470 µF max.
220 µF max.
(for each output)
100 µF max.
(for each output)
– 40 °C ... + 85 °C
+ 100 °C max.
– 55 °C ... + 125 °C
3.5% /K above 70°C
95 % rel H max.
>1 Mio. h @ + 25 °C
1’500 VDC
350 pF typ
> 1‘000 M Ohm
300 kHz typ. (Pulse frequency modulation PFM)
UL/cUL 60950 , IEC 60950, EN 60950
Input/Output
Input/Output
Input/Output (500 VDC)
6 Watt
Output Specifications
Voltage set accuracy
Regulation
Ripple and noise
(20 MHz Bandwidth)
Temperature coefficient
Current limitation
Short circuit protection
Capacitive load
General Specifications
Temperature ranges
Derating
Humidity
(non condensing)
Reliability, calculated MTBF
(MIL-HDBK-217 E)
Isolation voltage
Isolation capacity
Isolation resistance
Switching frequency
Safety standards
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3