欢迎访问ic37.com |
会员登录 免费注册
发布采购

TMC262-EVAL 参数 Datasheet PDF下载

TMC262-EVAL图片预览
型号: TMC262-EVAL
PDF下载: 下载PDF文件 查看货源
内容描述: 电源驱动步进电机 [POWER DRIVER FOR STEPPER MOTORS]
分类和应用: 电机驱动
文件页数/大小: 58 页 / 1458 K
品牌: TRINAMIC [ TRINAMIC MOTION CONTROL GMBH & CO. KG. ]
 浏览型号TMC262-EVAL的Datasheet PDF文件第38页浏览型号TMC262-EVAL的Datasheet PDF文件第39页浏览型号TMC262-EVAL的Datasheet PDF文件第40页浏览型号TMC262-EVAL的Datasheet PDF文件第41页浏览型号TMC262-EVAL的Datasheet PDF文件第43页浏览型号TMC262-EVAL的Datasheet PDF文件第44页浏览型号TMC262-EVAL的Datasheet PDF文件第45页浏览型号TMC262-EVAL的Datasheet PDF文件第46页  
TMC262 DATASHEET (Rev. 2.07 / 2013-FEB-14)
42
Status
OTPW
OT
Description
Range
Overtemperature warning. This bit indicates 0 / 1
whether the warning threshold is reached.
Software can react to this setting by reducing
current.
Overtemperature shutdown. This bit indicates 0 / 1
whether the shutdown threshold has been
reached and the driver has been disabled.
Comment
1: temperature
prewarning level
reached
1:
driver shut down
due to over-
temperature
11.4 Undervoltage Detection
The undervoltage detector monitors both the internal logic supply voltage and the supply voltage. It
prevents operation of the chip when the MOSFETs cannot be guaranteed to operate properly because
the gate drive voltage is too low. It also initializes the chip at power up.
In undervoltage conditions, the logic control block becomes reset and the driver is disabled. All
MOSFETs are switched off. All internal registers are reset to zero. Software also should monitor the
supply voltage to detect an undervoltage condition. If software cannot measure the supply voltage,
an undervoltage condition can be detected when the response to an SPI command returns only zero
bits in the response and no bits are shifted through the internal shift register from SDI to SDO. After
a reset due to undervoltage occurs, the CS parameter is cleared, which is reflected in an SE status of 0
in the read response.
V
VS
V
UV
ca. 100µs
ca. 100µs
Time
Device in reset: all
registers cleared to 0
Reset
Figure 11.2 Undervoltage reset timing
Note: Be sure to operate the IC significantly above the undervoltage threshold to ensure reliable
operation! Check for SE reading back as zero to detect an undervoltage event.
www.trinamic.com