Tri path Technol og y, I nc. - Techni cal I nformation
SYMBOL
V
DD
V5
SLEEP
MUTE
T
STORE
T
A
T
J
Supply Voltage
PARAMETER
Input Section Supply Voltage
SLEEP Input Voltage
MUTE Input Voltage
Storage Temperature Range
Operating Free-air Temperature Range
Junction Temperature
Value
16
6.0
-0.3 to 6.0
-0.3 to V5+0.3
-40 to 150
0 to 70
150
UNITS
V
V
V
V
°C
°C
°C
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur.
Note 2: See Power Dissipation Derating in the Applications Information section.
O P E R A T I N G C O N D I T I O N S
(Note 4)
SYMBOL
V
DD
V
IH
V
IL
Supply Voltage
High-level Input Voltage (MUTE, SLEEP)
Low-level Input Voltage (MUTE, SLEEP)
PARAMETER
MIN.
8.5
3.5
1
TYP.
12
MAX.
13.2
UNITS
V
V
V
Note 3: Recommended Operating Conditions indicate conditions for which the device is functional. See
Electrical Characteristics for guaranteed specific performance limits.
THERMAL CHARACTERISTICS
SYMBOL
θ
JC
θ
JA
PARAMETER
Junction-to-case Thermal Resistance
Junction-to-ambient Thermal Resistance (still air)
VALUE UNITS
2.5
50
°
C/W
°
C/W
2