欢迎访问ic37.com |
会员登录 免费注册
发布采购

3G-18-180 参数 Datasheet PDF下载

3G-18-180图片预览
型号: 3G-18-180
PDF下载: 下载PDF文件 查看货源
内容描述: 180瓦电源适配器 [180 WATT POWER ADAPTERS]
分类和应用:
文件页数/大小: 2 页 / 213 K
品牌: TRUMPOWER [ Tumbler Technologies + TRUMPower ]
 浏览型号3G-18-180的Datasheet PDF文件第2页  
TRUMPower
D E S C R IP T IO N
The 3G & 3RG series of AC/DC desktop power
adapters are capable of delivering 180 watts
continuous DC power. They are enclosed in a
94V-1 rated polyphenylene-oxide case with an IEC
320/C14 or IEC 320/C6 inlet to mate with
interchangeable cord for world-wide use. All
model meet CISPR 22 and FCC class B emission
limits, and comply with UL, CSA, IEC and CE
requirements.
180 WATT POWER ADAPTERS
3G & 3RG SERIES
RoHS
F E AT U R E S
High Efficiency
Low Ripple & Noise
O v e r v o l ta g e p r o t e c t i o n
Short-circuit protection
Overpow er protection
Over temperature protection
100% burn-in at full rated load
C o m p l i a n t w i t h C E C a n d E n e r g y S ta r e f f i c i e n c y
l e v e l I V r e q u i r e m e n ts
No load power consumption less than 0.5W
Av e r a g e a c t i v e e f f i c i e n c y
8 5 %
C o m p l i a n t w i t h R o H S r e q u i r e m e n ts
S a f e t y Sta n d a r d A p p r o va l s
UL 60950
CSA C22.2 No. 60950
TÜV EN60950-1
I N P U T S P E C I F I C AT I O N S
I n p u t v o l ta g e
Input frequency
Input current
Earth leakage current:
( To u c h c u r r e n t )
9 0 t o 2 6 4 VA C
47 to 63 Hz
2 . 5 A
r m s
f o r 11 5 VA C
1 . 2 5 A
r m s
f o r 2 3 0 VA C
1 5 0 µ A m a x . @ 11 5 VA C , 6 0 H z
2 5 0 µ A m a x . @ 2 3 0 VA C , 5 0 H z
GENERAL SPECIFICATIONS
Hold-up time:
Turn on delay time:
Power Factor:
Efficiency:
Line regulation:
Inrush current:
5 msec minimum at 100VAC or
240VAC
3 sec maximum at 100VAC
0.95 typical
87% minimum at 100VAC or 240VAC.
±0.5% maximum at full load
120A max. @ 240VAC cold start
OUTPUT SPECIFICATIONS
Output voltage/current:
Total output power:
Ripple and noise:
See rating chart
See rating chart
380mV peak to peak maximum
Withstand voltage:
3000VAC from input to output
1500VAC from input to ground
MTBF:
100,000 hours at full load at
25ºC ambient, calculated per
MIL-HDBK- 217F
EMC Performance (EN55024)
EN55022:
Class B conducted, Class B radiated
FCC:
Class B conducted, Class B radiated
VCCI:
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion, Class D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8KV air and ±4KV contact
EN61000-4-3:
R a d i a t e d i m m u n i t y, 3 V / m
EN61000-4-4:
Fast transient/burst, ±1KV
EN61000-4-5:
Surge, ±1KV diff, ±2KV com.
EN61000-4-6:
C o n d u c t e d i m m u n i t y, 3 Vr m s
EN61000-4-8:
M a g n e t i c f i e l d i m m u n i t y, 1 A / m
E N 6 1 0 0 0 - 4 - 11 :
Vo l t a g e d i p s , 3 0 % r e d u c t i o n f o r
500ms and >95% reduction for
10ms
O v e r v o l ta g e p r o t e c t i o n
Set at 110-140% of its nominal
output voltage
O v e r c u r r e n t p r o t e c t i o n
All models protected to short
circuit conditions
Te m p e r a t u r e
All outputs ±0.04%/ºC maximum
coefficient
Tr a n s i e n t r e s p o n s e
Maximum excursion of 4% or
better on all models, recovering
to 1% of final value within 500µs
after a 25% step load change
E N V I R O N M E N TA L S P E C I F I C AT I O N S
O p e r a t i n g t e m p e r a t u r e
0ºC to +40ºC
Storage temperature
-20ºC to +80ºC
Relative humidity
10% to 90% non-condensing
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616
Fax: 408-988-6622
email: sales@trumpower.com