110 WATT DC TO DC CONVERTERS
DESCRIPTION
The PD110 series of DC/DC converters provide up to 110 watts
of continuous output power. Available in three standard input
range of 10-20 VDC, 18-36 VDC and 36-72 VDC, they are
ideal for a variety of applications including telecoms, portable
equipment and vehicle mounted instrumentation. All units
are available in compact “open PCB” or “enclosed” mechanical
formats.
PD110 SERIES
F E ATU R E S
Low cost
Small size, light weight
100
burn-in
Overvoltage protection
Overcurrent protection
Three wide input ranges:
10-20 VDC, 18-36 VDC and 36-72 VDC
I N P U T S P E C I F I C ATI O N S
Input voltage
1 0 t o 2 0 V D C
P D 11 0 “ L ” s e r i e s
1 8 t o 3 6 V D C( P D 11 0 “ M ” s e r i e s
3 6 t o 7 2 V D C
P D 11 0 “ H ” s e r i e s
15A
rms
for 12VDC
9.4A
rms
for 24VDC
4.7A
rms
for 48VDC
E N V I R O N M E N TA L S P E C I F I C ATI O N S
Operating temperature
St o r a g e t e m p e r a t u r e
Relative humidity
Derating
0
to +70
-40
to +85
5
to 95
non-condensing
Derate from 100
at +50
linearly to 50
at +70
Input current
OUTPUT SPECIFICATIONS
Output voltage/current:
Total output power:
Ripple and noise:
See rating chart
110 watts maximum
1﹪ peak to peak max.
GENERAL SPECIFICATIONS
Switching frequency:
Efficiency:
Line regulation:
Withstand voltage:
MTBF:
50KHz ±5KHz
70﹪ minimum at full load
±0.5﹪ maximum at full load
1000VDC from input to output
400,000 hours minimum at full load
at 25℃ ambient, calculated per
MIL-HDBK-217F
Overvoltage protection:
set at 112 - 132﹪ of its nominal
output voltage
All outputs protected to short
circuit conditions
All outputs ±0.04﹪ /℃
maximum
Maximum excursion of 4﹪ or
better on all models, recovering
to 1﹪ of final value within
500us after a 25﹪ step load
change
Overcurrent protection:
Temperature coefficient:
Transient response:
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616
sales@trumpower.com
www.TRUMPower.com