TS200 Series
200W Compact AC/DC Power Supplies
Universal AC input / Full range
Built-in active PFC function
High efficiency up to 90% (typ)
Protections: Short circuit / Overload / Over voltage / Over temperature
PWM control and regulated
High power density 9.78W/inch
3
5"x3" compact size
Built-in remote sense function
ZVS technology to reduce power dissipation
Free air convection for 150W and 200W with 20.5 CFM forced air
3 years warranty
Features :
SPECIFICATION
MODEL
PART NO.
DC VOLTAGE
RATED CURRENT
TS200-05
PPS-200-5
5V
36A
TS200-12
PPS-200-12
12V
16.6A
0 ~ 12.5A
0 ~ 16.6A
150W
199.2W
100mVp-p
10.8 ~ 13.2V
3.0%
0.5%
1.0%
TS200-15
PPS-200-15
15V
13.3A
0 ~ 10A
0 ~ 13.3A
150W
199.5W
100mVp-p
13.5 ~ 16.5V
3.0%
0.5%
1.0%
TS200-24
PPS-200-24
24V
8.3A
0 ~ 6.25A
0 ~ 8.3A
150W
199.2W
150mVp-p
21.6 ~ 26.4V
2.0%
0.5%
1.0%
TS200-27
PPS-200-27
27V
7.4A
0 ~ 5.56A
0 ~ 7.4A
150W
199.8W
150mVp-p
24.3 ~ 30V
2.0%
0.5%
1.0%
TS200-48
PPS-200-48
48V
4.167A
0 ~ 3.13A
0 ~ 4.167A
150W
200W
250mVp-p
43.2 ~ 52.8V
2.0%
0.5%
1.0%
CURRENT RANGE (convection)
0 ~ 26A
CURRENT RANGE (20.5CFM FAN)
0 ~ 36A
RATED POWER (convection)
130W
RATED POWER (20.5CFM FAN)
180W
OUTPUT
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
4.5 ~ 5.5V
4.0%
0.5%
1.0%
1200ms, 60ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
PF>0.93/230VAC
86%
2500ms, 60ms/115VAC at full load
12ms/230VAC/115VAC at full load
127 ~ 370VDC
PF>0.98/115VAC at full load
89%
89%
89%
89%
90%
2.2A/115VAC
1.2A/230VAC
COLD START 70A/230VAC
<2mA / 240VAC
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.6 ~ 7.25V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
31.05 ~ 36.45V
57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
SAFETY &
(Note 4)
EMC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
108.4Khrs min. MIL-HDBK-217F (25
127*76.2*34.6mm (L*W*H)
0.37Kg; 36pcs/14.3Kg/0.79CUFT
)
OTHERS
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Heat Sink HS1,HS2 can not be shorted.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
Tumbler Technologies + TRUMPower
• Santa Clara, CA, USA • 408-988-6616 • sales@trumpower.com •
www.TRUMPower.com