型号: SF5512
PDF下载: 下载PDF文件 查看货源
内容描述: 480.00 MHz的SAW滤波器 [480.00 MHz SAW Filter]
分类和应用:
文件页数/大小: 2 页 / 255 K
品牌: VANLONG [ VANLONG TECHNOLOGY CO., LTD. ]
 浏览型号SF5512的Datasheet PDF文件第2页  
480.00 MHz SAW Filter
Ideal for DBS Receivers, IF Filter
Constant Group Delay
Improved ESD capability by integrated shunt resistors
Ultra Miniature Ceramic QCC8C SMD Package
Complies with Directive 2002/95/EC (RoHS Compliant)
SF5512
Absolute Maximum Rating (Ta=25°C)
Parameter
AC Voltage Between Any Two Pins
DC Voltage Between Any Two Pins
Operating Temperature Range
Storage Temperature Range
V
PP
V
DC
Rating
5
0
-25 ~ +85
-40 ~ +85
Unit
V
V
°C
°C
T
A
T
stg
Electronic Characteristics
Parameter
Center Frequency (25°C)
Between 3dB point
Tolerance from 480.00 MHz
Insertion Attenuation
3dB Bandwidth
Relative Attenuation
466.50 MHz
493.50 MHz
Lower Sidelobe
Upper Sidelobe
430.00 … 455.50 MHz
504.50 … 530.00 MHz
-
0.1µs … 2.0µs after main pulse
Amplitude Ripple (p-p)
Group Delay
Group Delay Ripple (p-p)
473.50 … 486.50 MHz
480.00 MHz
467.00 … 493.00 MHz
-
3.0
3.2
46
43
46.0
0.6
227.5
8.5
-86
4.6
4.6
-
-
-
1.0
-
15.0
-
dB
dB
dB
dB
dB
dB
ns
ns
ppm/K
Sym
f
C
Minimum
NS
-
-
25.60
Typical
480.00
-
22.5
26.60
Maximum
NS
1.0
24.0
27.60
Unit
MHz
MHz
dB
MHz
f
C
α
BW
3
α
rel
-
40
38
40.0
-
-
-
-
Reflected Wave Signal Suppression
∆α
τ
∆τ
FTC
Temperature Coefficient of Frequency
NS = Not Specified
Notes:
1.
The frequency
f
C
is defined as the midpoint between the 3dB
frequencies.
Unless noted otherwise, all measurements are made with the filter
installed in the specified test fixture that is connected to a 50Ω test
system with VSWR
1.2:1. The test fixture L and C are adjusted
for minimum insertion loss at the filter center frequency,
f
C
. Note
that insertion loss, bandwidth, and passband shape are dependent
on the impedance matching component values and quality.
Unless noted otherwise, specifications apply over the entire
specified operating temperature range.
The specifications of this device are based on the test circuit
5.
shown above and subject to change or obsolescence without
notice.
All equipment designs utilizing this product must be approved by
the appropriate government agency prior to manufacture or sale.
Our liability is only assumed for the Surface Acoustic Wave (SAW)
component(s) per se, not for applications, processes and circuits
implemented within components or assemblies.
For questions on technology, prices and delivery please contact
our sales offices or e-mail sales@vanlong.com.
2.
6.
3.
7.
4.
Phone: +86 (10) 5128 1211
Fax: +86 (10) 5820 3915
Email: sales@vanlong.com
Web: http://www.vanlong.com
SF5512
©
October 2006 by Vanlong Technology Co., Ltd.