VL-FS-MGLS128128-44C REV. A
(MGLS128128T-HT-HV-G-LED05W -TH)
MAY/2006
PAGE 7 OF 12
4. Absolute Maximum Ratings
4.1 Electrical Maximum Ratings-for IC Only
Table 3
Symbol
VDD - VSS
VLCD=VDD – V0
Vin
Parameter
Min.
Max.
Unit
Supply voltage (Logic)
-0.3
+7.0
V
Supply voltage (LCD drive)
-0.3
+28.0
V
Input voltage
-0.3
VDD +0.3
V
Note:
The modules may be destroyed if they are used beyond the absolute maximum ratings.
All voltage values are referenced to VSS = 0V.
4.2 Environmental Conditions
Table 4
Operating
Storage
Item
Temperature
Temperature
(Topr)
(Tstg) (Note 1)
Min.
Max.
Min.
Max.
Ambient Temperature
-20°C
+70°C
-30°C
+80°C
90% max. RH for Ta
≤
40°C
Humidity(Note 1)
<50%RH for 40°C <Ta≤ Maximum operating temperature
Vibration (IEC 68-2-6) Frequency: 10∼55 Hz
cells must be mounted
Amplitude: 0.75mm
on a suitable connector Duration: 20 cycles in each direction.
Shock (IEC 68-2-27)
Pulse duration: 11 ms
Half-sine pulse shape
Peak acceleration: 981m/s
2
= 100 g
Number of shocks: 3 shocks in 3 mutually perpendicular
axes.
Note (1): Product cannot sustain at extreme storage conditions for long time.
Remark
Dry
No
condensation
3 directions
3 directions