VL-FS-MDLS12433P-01 REV. A
(MDLS12433P-LV-S)
MAR/2004
PAGE 6 OF 10
3.
Absolute Maximum Ratings
3.1
Electrical Maximum Ratings (Ta = 25 ºC)
Table 2
Parameter
Condition
-
Symbol
Min.
-0.5
0
Max.
+8.0
11.0
Unit
V
Power supply voltage (Logic)
Power supply voltage (LCD)
Input voltage range
VCC - GND
VLCD
V
OSC,SCL,SDA
Vin
GND-0.50 VCC +0.5
V
Note:
The modules may be destroyed if they are used beyond the absolute maximum ratings.
All voltage values are referenced to GND = 0V.
3.2
Environmental Condition
Table 3
Operating
Storage
Item
Temperature
(Topr)
Temperature
(Tstg)
Remark
Min.
0°C
Max.
+50°C
Min.
Max.
+60°C
Ambient Temperature
Humidity
Dry
-10°C
no condensation
95% max. RH for Ta ≤ 40°C
< 95% RH for Ta > 40°C
Frequency: 10 ∼ 55 Hz
Amplitude: 0.75 mm
Vibration (IEC 68-2-6)
cells must be mounted
on a suitable connector
Shock (IEC 68-2-27)
Half-sine pulse shape
3 directions
Duration: 20 cycles in each direction.
Pulse duration : 11 ms
3 directions
Peak acceleration: 981 m/s2 = 100g
Number of shocks : 3 shocks in 3
mutually perpendicular axes.