FX-104 Frequency Translator
Outline Drawing
Pin Out
Pin
1
Symbol
CLKIN
Function
Input Frequency
- The FX-104 series AC couples the input, this means the unit is capable of
handling HCMOS, LvHCMOS, PECL and LvPECL input signals.
(For Input Frequencies below 1 MHz only HCMOS and LvHCMOS are supported)
Ground
Lock Detect
Logic “1” indicates a locked condition
Logic “0” indicates that no input signal is present or the input signal has moved out of the
lock range.
PLL/ VCXO control voltage
Under locked conditions, should be >0.3V and <3.0V for the 3.3 volt option or >0.5V and
<4.5V for the 5 volt option. Input frequency may be out of range if voltage exceeds these limits.
Missing
No Connection
Ground
No connect
Logic “0”
Output
Complementary Output
No Connection
Do not Exceed Vcc
Do not Exceed Vcc
No Connection
Ground
Power Supply Voltage (5 Vdc or 3.3Vdc)
=
=
Output enabled
Output disabled
2
3
GND
LD
(output)
4
Monitor
(Output)
---
NC
GND
Enable
Disable
Out
COUT
NC
Select A
Select B
NC
GND
V
cc
5
6
7
8
9
10
11
12
13
14
15
16
Vectron International •
267 Lowell Road, Hudson, NH 03051
• Tel: 1-88-VECTRON-1 • Web: www.vectron.com