TFS1880.doc
version 1.2
08.01.2004
VI
TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances
for input:
for output:
23 C
0 dBm
50
50
Preliminary Specification
TFS 1880
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency
f
N
is fixed at 1880 MHz without any tolerance or
limit. The values of absolute attenuation a abs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
Nominal frequency
Centre frequency
Pass band
Pass band ripple
Absolute attenuation
10
1930
1935
2032
2340
3000
VSWR
MHz
MHz
MHz
MHz
MHz
MHz
...
...
...
...
...
...
1720
1935
1990
2340
3000
3500
within
aabs
MHz
MHz
MHz
MHz
MHz
MHz
PB
ae
fN
fC
PB
typ. value
3,4
-
1880
80,5
0,6
MHz
MHz
dB
fN
max.
dB
max.
tolerance/limit
5
1880
-
30
3,5
MHz
dB
dB
MHz
33
17
41
41
37
12
2,1
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
max.
30
13
20
35
30
10
2,5:1
dB
dB
dB
dB
dB
dB
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
Input power level
*
)
f(Hz) = TCf(ppm/K) x (T-T
0
) x fTo(MHz)
- 10
°C
... + 70
°C
-
TCf*
-36 ppm/K
-
max.
- 40
°C
... + 85
°C
-
13
dBm
generated:
checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability
is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or