VI
TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
Filter specification
TFS 243E
1/5
350
|| -3,8 pF
350
|| -3,8 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 243E is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 243,0 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
Insertion loss
(reference level)
Nominal frequency
Passband
Pass band ripple
Bandwidth
0,5 dB
3
dB
Relative attenuation
f
N
f
N
f
N
f
N
f
N
±
±
±
±
±
0,50
1,00
3,00
5,00
8,00
MHz
MHz
MHz
MHz
MHz
f
N
f
N
f
N
f
N
f
N
±
±
±
±
±
1,00
3,00
5,00
8,00
20,00
arel
MHz
MHz
MHz
MHz
MHz
BW
ae
typ. value
1,35
-
dB
tolerance / limit
max.
2,5
243,0
f
N
± 25
dB
MHz
kHz
dB
f
N
PB
0,15
dB
max.
±0,5
-
440
min.
KHz
± 25
-
kHz
15
30
37
43
48
-
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
max.
7
25
25
25
40
15
dB
dB
dB
dB
dB
dBm
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
TCf **
OTR
-
-
-0,032
ppm/K
2
- 40 °C ... + 85°C
- 45 °C ... + 90°C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**)
∆f(Hz)
= TCf(ppm/K
2
) x (T-T
0
)
2
x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.