Filename: tfs 315k.doc
Version 1.1
01.03.2006
VI
TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
50
50
°C
dBm
Ω
Ω
Filter specification
TFS 315K
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency
f
N
is fixed at 315,00 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Centre frequency 3dB
Passband
Pass band ripple
Absolute attenuation
f
N
f
N
f
N
f
N
f
N
f
N
f
N
f
N
-
-
-
-
+
+
+
+
0,3
305,0
22,0
11,0
10,4
21,1
42,5
85,0
MHz … f
N
MHz … f
N
MHz … f
N
MHz … f
N
MHz
MHz
MHz
MHz
…
…
…
…
f
N
f
N
f
N
f
N
+
-
-
-
+
+
+
+
0,3
27,0
21,1
10,4
11,0
22,0
43,7
685,00
arel
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
ae = amin
typ. value
1,5
-
315,0
MHz
dB
tolerance / limit
max.
2,0
315,0
-
f
N
± 0,3
MHz
dB
dB
MHz
f
N
f
C
PB
0,2
dB
max.
1,2
0,2
53
56
63
29
55
72
62
-
-
dB
dB
dB
dB
dB
dB
dB
dB
max.
min.
min.
min.
min.
min.
min.
min.
max.
max.
1,2
50
45
35
18
37
55
40
1,6 : 1
dB
dB
dB
dB
dB
dB
dB
dB
VSWR within PB
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*)
∆f(Hz)
= TCf(ppm/K) x (T-T
0
) x fcat(MHz).
**) 1 minute
14,8** dBm
OTR
TCf *
-
-
- 30
ppm/K
- 40 °C ... + 85°C
- 45 °C ... + 90°C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.