TFS70AP.doc
version 1.0
23.04.2004
VI
TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
23
°C
0 dBm
Input:
Output:
Filter Specification
TFS 70 AP
1/5
142
Ω
|| -56 pF
105
Ω
|| -64 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 70,00 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation
arel of the TFS 70AP is the insertion loss ae
.
The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1,5 dB filter
attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
Insertion loss
Nominal frequency
Pass band
Amplitude ripple
Deviation from linear phase
Triple transit suppression
Relative attenuation
fN
±
0,630
MHz
ae
fN
PB
PB
typ. value
19,5
dB
-
-
0,5
1
50
dB
deg
dB
max.
22
tolerance/limit
dB
MHz
MHz
dB
deg
dB
70,00
fN
±
0,61
max.
max.
min.
0,7
5
30
arel
0,7
40
60
-
-
TCf
-0,04
ppm/K
2
dB
dB
dB
max.
min.
min.
1,5
35
50
dB
dB
dB
f
±
0,750 MHz
N
f
±
0,900 MHz
N
Operating temperature range
Storage temperature range
Temperature coefficient of frequency **)
- 5 °C ... + 65 °C
- 40 °C ... + 85 °C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**)
∆f
c(Hz) = Tc
f
(ppm/K²) x (T-TA)² x fcat(MHz)
generated:
checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.