VTC4 Data Sheet
Performance Characteristics
Table 1. Electrical Performance for the Clipped Sine Wave Output Option
Parameter
Symbol
Min
Typical Maximum
Frequency
f
O
10.000
27.000
Typical Supply Voltage
2.8V, 3.0V, 3.3V or 5.0V
Ordering option, see last page
Supply Current
I
DD
10.000 MHz to < 15.000 MHz
1.5
15.000 MHz to 27.00 MHz
2.0
Output Level
Vp/p
0.8
Output Load
10K II 10pf
Control Voltage Impedance
Z
Vc
1
Control Voltage to reach pull
All options (5.0, 3.3,3.0 and 2.8V)
0.5
2.5
Pull Range
TPR
±5, ±8, ±10, ±15 or ±20
Ordering option, see last page
Temperature Stability
±0.5 to ±5.0
Ordering option, see last page.
Initial Accuracy, “No Adjust” option
±0.5
Power Supply Stability
±0.2
Load Stability
±0.2
Aging
±1.0
Operating temperature
0/55, -10/60, -20/70, -30/80, -40/85
Ordering option, see last page
Phase Noise, 12.800MHz
10 Hz offset
-89
100 Hz offset
-113
1 kHz offset
-137
10 kHz offset
-150
100 kHz offset
-155
5MHz offset
-156
Start-up time
2
Units
MHz
mA
V
Mohm
V
ppm
ppm
ppm
ppm
ppm
ppm/year
°C
dBc/Hz
ms
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.
Vectron International 267 Lowell Rd, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail: vectron@vectron.com