Package Options
Frequency Range
Standard
Frequencies
Mode
D1
= UM-1
7.0 MHz to 200.0 MHz
See
Standard Frequency Table
1
= Fundamental (7 to 50 MHz)
3=
3
rd
Overtone (30 to 120 MHz)
5
= 5
th
Overtone (80 to 200 MHz)
A
= ±100 PPM -20°C to +70°C
B
= ±50 PPM -20°C to +70°C
C
= ±100 PPM -40°C to +85°C
D
= ±50 PPM -40°C to +85°C
E
= ±25 PPM -20°C to +70°C
G
= ±10 PPM -20°C to +70°C
0
= Series Resonant
1=16pF
2=20pF
3=32pF
4=18pF
5=10pF
6=30pF
±25 PPM at +25°C
Tolerances to ±10 PPM are available
Stability Options
Load Capacitance
STD Calibration
Tolerance
Equivalent Series
Resistance
Shunt Capacitance
Drive Level Crystal
Aging Standard
Packaging Typical
P/N
7 to 16 MHz 80Maximum 16 to
120 MHz 40Maximum 120 to 200
MHz 100Maximum
7 pF Maximum
10 to 2,000 uW
<5 ppm/1
Bagged
VXD1-3B0-80M000
st
year
D1
= UM-1 package
3
= 3
rd
Overtone
B
= ±50 PPM -20°C to +70°C