内容描述: 这些ConverterPAC是滑动式的MegaPAC或电源中使用的输出组件家庭 [ConverterPACs are the family of slide-in output assemblies used in MegaPAC power supplies]
分类和应用:
文件页数/大小: 1 页 / 177 K
品牌: VICOR [ VICOR CORPORATION ]
   
ConverterPAC Description  
ConverterPACs are the family of slide-in output assemblies used in MegaPAC power supplies. There are  
currently 12 ConverterPACs available for use. Most ConverterPACs of the same length are interchange-  
able within a MegaPAC and between different AC input MegaPAC chassis. They can be added, moved,  
or changed as necessary. The type of ConverterPAC used in this slot is a DualQPAC.  
DualQPAC (LD)  
The DualQPAC output assembly consists of two 1st Gen VI-J00 DC to DC converters that  
provide two isolated output voltages. DualQPACs can provide up to 100 Watts of out-  
put power from each output. The DualQPACs are fused with a PC-Tron, DC-rated,  
fast-acting fuse. An active preload ensures the DC to DC converter operates in its  
highest noise performance range. As the load on the module increases, the preload  
removes itself from the circuit. Ripple and common mode noise filters on the output  
reduce ripple under any load conditions to 10mV p-p or 0.15% whichever is greater.  
On DualQPACs, the customer has access to the Trim pin on the module and can adjust  
the output voltage using an external circuit. OVP and OTL is not available. Please note  
that for the DualQPAC the output voltage from either output terminal to chassis should not  
exceed 100 Vdc, or peak. DualQPACS can only be used in the extended length MegaPACs.  
Newer DualQPACs have Autosense. This feature automatically locally senses the output if remote sense  
is not used. To check if an output has the Autosense feature, measure the impedance from the + Out to  
+ Sense and - Out to - Sense pins. If the impedance is 5 ohms, then the output has Autosense and does  
not require local sense jumpers. If a unit does not have Autosense, sense connections must be made For  
further technical information about ConverterPACs, contact Applications Engineering at 1-800-927-9474.  
Options available for DualQPAC  
+
OPTIONS  
D Power Good  
AVAILABILITY  
OPTIONAL  
+
T
Trim +/-10%  
Trim: +10%/-50%  
NOT AVAILABLE  
NOT AVAILABLE  
+
F
+
The customer has access to the Trim pin on the module and can adjust the output voltage using an external circuit.  
DualQPAC Output and Connector Pin Identification  
J1-B  
J1-B-PIN1  
J2-PIN1  
(OUTPUT CONNECTORS)  
Output connector kits (optional) for your  
MegaPAC supply are available for  
purchase from Westcor:  
Part Number  
MATING HDWR:  
1 AND 4 +V OUT  
2 AND 5 -V OUT  
4
5
6
1
2
HOUSING- MOLEX P/N: 39-01-2060  
TERMINALS- MOLEX P/N: 39-00-0039  
CRIMP TOOL MOLEX P/N: 11-01-0197  
TRIM TOP  
TRIM BOT  
N/C  
7
6
5
4
3
2
3 +R/SENSE 6 -R/SENSE  
3
Single phase  
Vcc IN  
input  
19-130040  
19-130041  
19-130042  
POWER GOOD  
Three phase  
input  
POWER GOOD INVERTED  
J1-A  
(OUTPUT CONNECTORS)  
1
SIGNAL GROUND  
MATING HDWR:  
DualQPAC  
output  
1 AND 4 +V OUT  
2 AND 5 -V OUT  
1
HOUSING- MOLEX P/N: 39-01-2060  
TERMINALS- MOLEX P/N: 39-00-0039  
CRIMP TOOL MOLEX P/N: 11-01-0197  
4
5
6
2
3
J1-A-PIN1  
3 +R/SENSE 6 -R/SENSE  
For more details about any Westcor products, contact the factory at 1-800-735-6200 or go to our website at  