BCM® in a VIA™ Package
Bus Converter
BCM4414xD1E13A3yzz
S
®
C
NRTL US
Isolated Fixed-Ratio DC-DC Converter
Features & Benefits
Product Ratings
• Up to 125A continuous low-voltage-side current
• Fixed transformation ratio (K) of 1/32
• Up to 711W/in3 power density
• 97.1% peak efficiency
VHI = 384V (260 – 410V)
ILO = up to 125A
K = 1/32
VLO = 12V (8.1 – 12.8V)
(no load)
Product Description
• Built-in EMI filtering and inrush limiting circuit
• Parallel operation for multi-kW arrays
• OV, OC, UV, short circuit and thermal protection
• 4414 package
The BCM4414xD1E13A3yzz in a VIA package is a high efficiency
Bus Converter, operating from a 260 to 410VDC high-voltage bus to
deliver an isolated 8.1 to 12.8VDC unregulated, low voltage.
This unique ultra-low profile module incorporates DC-DC
conversion, integrated filtering and PMBus commands and controls
in a chassis or PCB mount form factor.
• High MTBF
The BCM offers low noise, fast transient response and
industry-leading efficiency and power density. A low-voltage-side
referenced PMBus compatible telemetry and control interface
provides access to the BCM’s configuration, fault monitoring, and
other telemetry functions.
• Thermally enhanced VIA package
• PMBus® management interface
• Suitable for Hot-Swap applications
Leveraging the thermal and density benefits of Vicor VIA packaging
technology, the BCM module offers flexible thermal management
options with very low top- and bottom-side thermal impedances.
Typical Applications
• 380VDC Power Distribution
When combined with downstream Vicor DC-DC conversion
components and regulators, the BCM allows the Power Design
Engineer to employ a simple, low-profile design, which will
differentiate the end system without compromising on cost or
performance metrics.
• Information and Communication
Technology (ICT) Equipment
• High-End Computing Systems
• Automated Test Equipment
• Industrial Systems
• High-Density Energy Systems
• Transportation
Size:
• Green Buildings and Microgrids
4.35 x 1.40 x 0.37in
[110.55 x 35.54 x 9.40mm]
Part Ordering Information
High‑Side
Voltage
Range
Max
High‑Side
Voltage
Max
Max
Product
Function
Package
Length
Package
Width
Package
Type
Product Grade
(Case Temperature)
Low‑Side Low‑Side
Voltage Current
Option Field
Ratio
BCM
44
14
x
D1
E
13
A3
y
zz
BCM =
Bus Converter
Module
02 = Chassis/PMBus
06 = Short Pin/PMBus
10 = Long Pin/PMBus
Length in
Width in
B = Board VIA
C = –20 to 100°C [a]
T = –40 to 100°C [a]
Internal Reference
Inches x 10 Inches x 10 V = Chassis VIA
[a] High-temperature current derating may apply; See Figure 1, specified thermal operating area.
BCM® in a VIA™ Package
Page 1 of 43
Rev 1.3