SPECIFICATIONS
(typical at T
BP
= 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
Parameter
Input voltage
Inrush limiting
Transient immunity
Min
180
Typ
270
Max
375
0.018
Unit
Vdc
A/μF
Exceeds limits of MIL-STD-704E/F
Notes
Continuous
OUTPUT SPECIFICATIONS
Parameter
Output current
Efficiency
Internal voltage drop
External capacitance
10
22
μF
96
98
3.0
Min
Typ
Max
3
5.0
Unit
A
%
@3 A, 100°C baseplate
See Figure 4 on page 4.
400 V
Notes
CONTROL PIN SPECIFICATIONS
Parameter
ON/OFF control
Enable (ON)
Disable (OFF)
Min
0.0
3.5
Typ
Max
1.0
5.0
Unit
Vdc
Vdc
Notes
Referenced to – Vout
100 kΩ internal pull-up resistor
SAFETY SPECIFICATIONS
Parameter
Dielectric withstand
Min
Typ
1,500
2,121
Max
Vrms
Vdc
Unit
Notes
Input/Output to Base
Input/Output to Base
EMI
Standard
MIL-STD-461E
Conducted emissions:
Conducted susceptibility:
Test Procedure
CE101, CE102
CS101, CS114, CS115, CS116
Notes
GENERAL SPECIFICATIONS
Parameter
Weight
Warranty
Min
Typ
3.3 (94)
2
Max
Unit
Ounces (grams)
Years
Notes
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM3
Rev. 2.4
Page 2 of 6
Set your site on VICOR at vicorpower.com