Portable X-Ray Power Supply
XRS040N100 • XRS050N200
ELECTRICAL RATINGS
Part
Number
XRS040N100
XRS050N200
V
MAX
kV
-40
-50
I
MAX
µA
100
200
SPECIFICATIONS
XRS040N100:
Input Voltage:
Reverse Polarity Protection:
Max. Output Power:
Output Voltage Range:
Output Current:
XRS050N200:
Input Voltage:
Reverse Polarity Protection:
Max. Output Power:
Output Voltage Range:
Output Current:
Electrical:
Output Ripple Voltage:
Load Regulation:
Line Regulation:
Filament Voltage:
Filament Current:
Interface Signals:
• Output Voltage Control
• Output Voltage Monitor
• Output Current Control
• Output Current Monitor
• Enable
Environmental:
• Storage Temperature
• Operating Temperature
-40°C to +85°C
-10°C to +50°C
0-4V = 0-100%
0-4V = 0-100%
0-4V = 0-100%
0-4V = 0-100%
+5VDC = ON, <1VDC = OFF
9-12VDC
None
10 Watts
-10kVDC to -50kVDC
0 to 200µA
XRS Series
< 1% peak to peak
1% for NL to FL change
1% over input range
2Vrms nominal
300mA Max.
7-12VDC
Series Diode
4 Watts
-10kVDC to -40kVDC
0 to 100µA
Features:
• Voltage & current programming
• Voltage & current monitoring
• Low ripple
• Excellent load & line regulation
• Light weight
XRS Series
The XRS series power supplies
provide up to 4 to 10 watts of
output power up to -40kV to -50kV
max. The outputs are fully
adjustable over the specified
operating range. Rugged and light
weight, the XRS series brings you
the features you need with the
proven reliability and quality built
into all VMI's products.
Dimensions: In. (mm)
All temperatures are ambient unless otherwise noted.
Data subject to change without notice.
Voltage Multipliers Inc.
8711 W. Roosevelt Ave.
Visalia, CA 93291 USA
Tel:
559.651.1402
Fax:
559.651.0740
www.voltagemultipliers.com
www.highvoltagepowersupplies.com