欢迎访问ic37.com |
会员登录 免费注册
发布采购

IBU61-202 参数 Datasheet PDF下载

IBU61-202图片预览
型号: IBU61-202
PDF下载: 下载PDF文件 查看货源
内容描述: 63W裸板开关电源工业设备 [63W Open frame switching power supplies for Industrial Equipment]
分类和应用: 开关
文件页数/大小: 2 页 / 384 K
品牌: VOLGEN [ VOLGEN KAGA ELECTRONICS INC. ]
 浏览型号IBU61-202的Datasheet PDF文件第2页  
IBU61 SERIES
63W Open frame switching power supplies for Industrial Equipment
Description:
The IBU61 series of compact, open frame constructed, AC/DC or DC/DC
switching mode power supplies provide 63 Watts of continuous output
power . They are ideally suited for use in CRT terminals, disc drive
systems, microprocess or based systems, portable equipments and
many other applications, all models are designed to meet the safety
requirements of UL/c-UL(UL 60950-1),TUV-Bauart(EN60950-1) and new
CE requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 85 to 280 VAC, 47 to 400 Hz or 100 to 400VDC
Internal EMI filter
Single to Quad Output
Input connector mates with screw terminal (DINKLE#ESK750V-02P)
Output connector mates with Molex housing 09-50-3081 and
Molex 2478 series crimp terminal
Output Voltage Available From 3 VDC Thru 48VDC
Input Surge Current and Over Load protection
Over voltage protection (Crowbar Design)
Size: 3"x5"x1.1"
Class I Insulation
Two Years Warranty
Power Fail Detect (Optional)
Safety Approvals :
BAUART
GEPRUFT
Product Safety
TYPE
APPROVED
Electrical Characteristics:
Sym.
Vin
Fin
Wo
Vo
Io
Iil
Iih
Irl
Irh
Eff
REG-i
REG-o
OVP
OCP
Ttr
Thold
Ts
Vrn
Ilk
Tc
CB
Typ.
Max. Unit
VAC
VDC
VAC
VDC
Hz
W
V
A
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/
°c
Parameter
Input Voltage
Input Frequency
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
Start Up Time
Ripple & Noise (Pe ak to Peak)
Safety Ground Leakage Curr ent
Temperature Coefficient
Test Conditions
Universal Input Voltage
Min.
90
264
106
350
85
280
Operating Voltage
100
400
47
400
Vin= Operating Voltage
0
63
See rating chart
See rating chart
Io=Full load, Vin=115VAC or 160VDC
1.6
Io=Full load, Vin=230VAC or 325VDC
0.8
Io=Full load, 25
°c
, Cool start,
12
15
Vin=115VAC or 160VDC
Io=Full load, 25
°c
, Cool start,
26
30
Vin=230VAC or 325VDC
Io=Full Load, Vin=230VAC or 325VDC
70
80
88
Io=Full Load
0.5
1
Vin=230VAC or 325VDC
3
6
112
132
110
150
Io=Full Load to Half Load,
5
Vin=100VAC or 140VDC
Io=Full Load, Vin=110VAC or 160VDC
16
Io=Full Load, Vin=100VAC or 140VDC 0.3
1
2
Full Load, Vin=85VAC or 100VDC
1
2
Io=Full Load, Vin=240VAC
0.4 0.45
All output
-0.05
0.05
Environmental :
Sym.
Toper
Tstg
Hr
Pd
Parameter
Te s t Conditions
Min.
Typ.
Max.
-20
-40
5
70
85
95
Unit
C
C
%
Operating Temperature
Storage Temperature
Relative Humidity
Derate linearly from 100% load at 50 C to 50% load at 70 C
Safety Specifications:
Sym.
Parameter
Te s t Conditions
Primary to secondary
Primary to ground
Test Voltage=500VDC
Vin=220VAC
Vin=110VAC
Min. Typ. Max.
4242
2121
50
B
B
Unit
VDC
VDC
M
CLASS
CLASS
Dielectric
Vps
for Primary Withstanding Voltage
to secondary
Dielectric Withstanding Voltage
Vpg
for Primary to Ground
Isolation Resistance
Ri
CISPR
EMI requirements for CISPR-22
FCC