LANK 10W Series
2:1 Wide Input Range
Single and Dual Output
10 Watt DC/DC Converter
SPECIFICATION (CONTINUED)
ENVIRONMENTAL
Operating Temperature (Ambient)
Operating Temperature (Case)
Storage Temperature
Lead Temperature
Humidity
Cooling
MTBF
PHYSICAL
Weight
Dimensions
Case Material
TEST CONDITIONS
Min
-40
-40
-40
Nom
Max
Unit
°C
°C
°C
°C
%
1.5mm from case for 10 seconds
MIL-HDBK-217F @ 25°C, Ground Benign
+60
+90
+125
260
95
Free air convection
1,000,000 Hours
17.3 grams
31.8(L) x 20.3(W) x 10.2(H) mm
Metal with non-conductive baseplate
OUTPUT VOLTAGE / CURRENT RATING CHART
Model Number
LANK1233W10
LANK1205W10
LANK1251W10
LANK1212W10
LANK1215W10
LANK1212DW10
LANK1215DW10
LANK2425W10
LANK2433W10
LANK2405W10
LANK2451W10
LANK2412W10
LANK2415W10
LANK2412DW10
LANK2415DW10
LANK4825W10
LANK4833W10
LANK4805W10
LANK4851W10
LANK4812W10
LANK4815W10
LANK4812DW10
LANK4815DW10
Input Voltage
Output
Voltage
3.3 VDC
5 VDC
5.1 VDC
12 VDC
15 VDC
±12 VDC
±15 VDC
2.5 VDC
3.3 VDC
5 VDC
5.1 VDC
12 VDC
15 VDC
±12 VDC
±15 VDC
2.5 VDC
3.3 VDC
5 VDC
5.1 VDC
12 VDC
15 VDC
±12 VDC
±15 VDC
Output Current
Min
Max
Input Current (Typ)
No Load
12 VDC
(9 – 18 VDC)
24 VDC
(18 – 36 VDC)
48 VDC
(36 – 75 VDC)
300mA
200mA
200mA
83mA
66.6mA
±42mA
±33mA
300mA
300mA
200mA
200mA
83mA
66.6mA
±42mA
±33mA
300mA
300mA
200mA
200mA
83mA
66.6mA
±42mA
±33mA
3000mA
2000mA
2000mA
833mA
666mA
±416mA
±333mA
3000mA
3000mA
2000mA
2000mA
833mA
666mA
±416mA
±333mA
3000mA
3000mA
2000mA
2000mA
833mA
666mA
±416mA
±333mA
40mA
20mA
10mA
Reflected Ripple Efficiency Max Capacitive
Current (Typ)
(Typ)
Load
Max Load
1006mA
82%
2200µF
1004mA
83%
2200µF
1024mA
83%
2200µF
60mA
957mA
87%
820µF
968mA
86%
470µF
957mA
87%
220µF
968mA
86%
150µF
377mA
83%
2200µF
485mA
85%
2200µF
479mA
87%
2200µF
489mA
87%
2200µF
40mA
479mA
87%
820µF
478mA
87%
470µF
473mA
87%
220µF
478mA
87%
150µF
188mA
83%
2200µF
243mA
85%
2200µF
239mA
87%
2200µF
244mA
87%
2200µF
40mA
240mA
87%
820µF
239mA
87%
470µF
236mA
87%
220µF
243mA
87%
150µF
NOTES
1. Specifications typical at +25°C, resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient Recovery Time is measured to within 1% error band for a step change in output of 75% to 100%.
3. Ripple and noise measured at 20MHz bandwidth.
4. The LANK 10W Series requires a minimum load on the output to maintain specified regulation. Operation under
no-load conditions will not damage these devices, however they may not meet all listed specifications.
5. All DC/DC converters should be externally fused on the front end for protection.
6. Other input and output voltages may be available, please contact factory.
7. Specifications subject to change without notice.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797