Product catalogue | PCB connection systems | PCB plug-in connectors | Pitch 3.81 mm (0.150 inch) | Socket connectors,  
screw clamp connection, pitch 3.81 | BCZ 3.81/90/270 | BCZ 3.81/90  
Material data  
Contact base material  
Contact surface  
Copper alloy  
tinned  
Connectable conductors  
Clamping range, min.  
Clamping range, max.  
AWG, min.  
0.08 mm²  
1.5 mm²  
28  
AWG, max.  
16  
Solid, min. H05(07) V-U  
Solid, max. H05(07) V-U  
Flexible, min. H05(07) V-K  
Flexible, max. H05(07) V-K  
0.2 mm²  
1.5 mm²  
0.2 mm²  
1.5 mm²  
With wire end ferrule, acc. to DIN 46 228/1, min. 0.2 mm²  
With wire end ferrule, acc. to DIN 46 228/1, max. 1.5 mm²  
w. plastic collar ferrule, DIN 46228 pt 4, min.  
w. plastic collar ferrule, DIN 46228 pt 4, max.  
Gauge to EN 60999 a x b; ø  
0.2 mm²  
1.5 mm²  
2.4 mm x 1.5 mm ; 2.4 mm  
DIN IEC rating data  
Rated current, min. No. pins (Tu=20°C)  
Rated current, max. No. pins (Tu=20°C)  
Rated current, min. No. pins(Tu=40°C)  
Rated current, max. No. pins (Tu=40°C)  
Rated voltage for overvoltage class/pollution  
severity II/2  
17.5 A  
15.9 A  
17.5 A  
14.1 A  
320 V  
Rated voltage for overvoltage class/pollution  
severity III/2  
Rated voltage for overvoltage class/pollution  
severity III/3  
160 V  
160 V  
Rated impulse withstand voltage for overvoltage 2.5 kV  
class/pollution severity II/2  
Rated impulse withstand voltage for overvoltage 2.5 kV  
class/pollution severity III/2  
Rated impulse withstand voltage for overvoltage 2.5 kV  
class/pollution severity III/3  
Short-time withstand current resistance  
3 x 1s with 76 A  
CSA rating data  
Rated voltage (Use group D)  
Rated current (Use group D)  
AWG conductor (field wiring), min.  
AWG conductor (field wiring), max.  
300 V  
10 A  
28  
16  
UL 1059 rating data  
Rated voltage (Use group D)  
Rated current (Use group D)  
AWG conductor, min.  
300 V  
10 A  
28  
AWG conductor, max.  
16  
- 2 -