1979850000 参数 Datasheet PDF下载

1979850000图片预览
型号: 1979850000
PDF下载: 下载PDF文件 查看货源
内容描述: BLF 5.00 / 08 / 90LR SN BK BX [BLF 5.00/08/90LR SN BK BX]
分类和应用: 端子和端子排
文件页数/大小: 3 页 / 75 K
品牌: WEIDMULLER [ WEIDMULLER ]
 浏览型号1979850000的Datasheet PDF文件第1页浏览型号1979850000的Datasheet PDF文件第3页  
Product catalogue | PCB connection systems | PCB plug-in connectors | Pitch 5.00 / 5.08 mm (0.197 / 0.200 inch) |  
Female PUSH IN socket block with spring connection in 5.00/5.08 pitch | BLF 5.00-5.08/90/270 | BLF 5.00/90LR SN  
Connectable conductors  
Clamping range, min.  
Clamping range, max.  
Conductor connection cross-section AWG, min.  
0.13 mm²  
3.31 mm²  
AWG 26  
Conductor connection cross-section AWG, max. AWG 12  
Solid, min. H05(07) V-U  
Solid, max. H05(07) V-U  
Stranded, max. H07V-R  
0.2 mm²  
2.5 mm²  
2 mm²  
Stranded, min. H07V-R  
0 mm²  
Flexible, min. H05(07) V-K  
Flexible, max. H05(07) V-K  
0.2 mm²  
2.5 mm²  
0.2 mm²  
2.5 mm²  
0.2 mm²  
2.5 mm²  
2.4 mm x 1.5 mm  
w. wire end ferrule, DIN 46228 pt 1, min  
with wire end ferrule, DIN 46228 pt 1, max.  
w. plastic collar ferrule, DIN 46228 pt 4, min.  
with plastic collar ferrule, DIN 46228 pt 4, max.  
Gauge to EN 60999 a x b; ø  
DIN IEC rating data  
Rated current, min. No. of poles (Tu=20°C)  
Rated current, max. No. of poles (Tu=20°C)  
Rated current, no. of poles (Tu=40°C), min.  
Rated current, no. of poles (Tu=40°C), max.  
Rated voltage for overvoltage class/pollution  
severity II/2  
18.5 A  
6 A  
12.5 A  
6 A  
400 V  
Rated voltage for overvoltage class/pollution  
severity III/2  
Rated voltage at overvoltage category/pollution  
degree III/3  
320 V  
250 V  
Rated impulse withstand voltage for overvoltage 4 kV  
class/pollution severity II/2  
Rated impulse withstand voltage for overvoltage 4 kV  
class/pollution severity III/2  
Rated impulse withstand voltage for overvoltage 4 kV  
class/pollution severity III/3  
Short-time withstand current resistance  
3 x 1s with 120 A  
CSA rating data  
Rated voltage (Use group B)  
Rated current (use group B)  
300 V  
10 A  
UL 1059 rating data  
Rated voltage (use group B)  
Rated current (use group B)  
300 V  
10 A  
Approvals  
Approvals institutes  
CSA; CURUS  
27-26-07-08  
Classifications  
eClass 6.0  
Notes  
Notes  
- 2 -