ISD4004 Series
Table 6: DC Parameters
(Packaged Parts)
Symbol
V
IL
V
IH
V
OL
V
OL1
V
OH
I
CC
Parameters
Input Low Voltage
Input High Voltage
Output Low Voltage
RAC, INT Output Low Voltage
Output High Voltage
V
CC
Current (Operating)
— Playback
— Record
V
CC
Current (Standby)
Input Leakage Current
MISO Tristate Current
Output Load Impedance
ANA IN+ Input Resistance
ANA IN– Input Resistance
ANA IN+ or ANA IN– to AUD OUT Gain
5
2.2
40
3.0
56
25
3.8
71
1
V
CC
– 0.4
V
CC
x 0.8
0.4
0.4
Min
(2)
Typ
(1)
Max
(2)
V
CC
x 0.2
Units
V
V
V
V
V
I
OL
= 10 µA
I
OL
= 1 mA
I
OH
= –10 µA
R
EXT
=
¥
(3)
R
EXT
=
¥
(3)
(3) (4)
Conditions
15
25
1
30
40
10
±1
10
mA
mA
µA
µA
µA
KW
KW
KW
dB
I
SB
I
IL
I
HZ
R
EXT
R
ANA IN+
R
ANA IN–
A
ARP
1.
2.
3.
4.
5.
(5)
Typical values: T
A
= 25°C and 3.0 V.
All min/max limits are guaranteed by ISD via electrical testing or characterization. Not all specifications are
100 percent tested.
V
CCA
and V
CCD
connected together.
SS = V
CCA
= V
CCD
, XCLK = MOSI = V
SSA
= V
SSD
and all other pins floating.
Measured with AutoMute feature disabled.
Table 7: AC Parameters
(Packaged Parts)
Symbol
F
S
Characteristic
Sampling
Frequency
ISD4004-08M
ISD4004-10M
ISD4004-12M
ISD4004-16M
ISD4004-08M
ISD4004-10M
ISD4004-12M
ISD4004-16M
ISD4004-08M
ISD4004-10M
ISD4004-12M
ISD4004-16M
Min
(2)
Typ
(1)
8.0
6.4
5.3
4.0
3.4
2.7
2.3
1.7
8
10
12
16
Max
(2)
Units
KHz
KHz
KHz
KHz
KHz
KHz
KHz
KHz
min
min
min
min
(5)
(5)
(5)
(5)
Conditions
F
CF
Filter Pass Band
3-dB Roll-Off Point
(3) (7)
3-dB Roll-Off Point
(3) (7)
3-dB Roll-Off Point
(3) (7)
3-dB Roll-Off Point
(3) (7)
(6)
(6)
(6)
(6)
T
REC
Record Duration
ISD
9