X25320
ABSOLUTE MAXIMUM RATINGS*
*COMMENT
Temperature under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
listed in the operational sections of this specification is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
Voltage on any Pin with Respect to V ......... –1V to +7V
SS
D.C. Output Current ............................................. 5mA
Lead Temperature
(Soldering, 10 seconds).............................. 300°C
RECOMMENDED OPERATING CONDITIONS
Supply Voltage
X25320
Limits
5V ±10%
Temp
Min.
0°C
Max.
+70°C
+85°C
Commercial
Industrial
Military
X25320-2.7
2.7V to 5.5V
–40°C
–55°C
3063 PGM T07.1
+125°C
3063 PGM T06.1
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Limits
Symbol
Parameter
Min.
Max.
Units
Test Conditions
SCK = V x 0.1/V x 0.9 @ 2MHz,
I
V
V
Supply Current (Active)
5
mA
CC
CC
CC
CC
CC
SO = Open, CS = V
SS
SS
I
I
I
Supply Current (Standby)
1
µA
µA
µA
V
CS = V , V = V
CC IN
or V
CC
SB
LI
Input Leakage Current
Output Leakage Current
Input LOW Voltage
10
10
V
V
= V
to V
CC
IN
SS
= V
to V
CC
LO
OUT
SS
(1)
V
V
V
V
V
V
–1
V
x 0.3
IL
CC
(1)
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
V
V
V
x 0.7
V
+ 0.5
V
IH
CC
CC
CC
CC
0.4
V
V
V
V
V
= 5V, I = 3mA
OL
OL1
OH1
OL2
OH2
CC
CC
CC
CC
– 0.8
– 0.3
V
= 5V, I
OH
= -1.6mA
0.4
V
= 3V, I = 1.5mA
OL
V
= 3V, I
OH
= -0.4mA
3063 PGM T08.3
POWER-UP TIMING
Symbol
Parameter
Min.
Max.
Units
(3)
t
Power-up to Read Operation
1
ms
PUR
(3)
t
Power-up to Write Operation
5
ms
PUW
3063 PGM T09
CAPACITANCE T = +25°C, f = 1MHz, V
= 5V.
A
CC
Symbol
Test
Max.
Units
Conditions
= 0V
(2)
C
C
Output Capacitance (SO)
8
6
pF
pF
V
OUT
OUT
(2)
IN
Input Capacitance (SCK, SI, CS, WP, HOLD)
V
= 0V
3063 PGM T10.1
IN
Notes: (1) VIL min. and VIH max. are for reference only and are not tested.
(2) This parameter is periodically sampled and not 100% tested.
(3) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
8