X25F064/032/016/008
ABSOLUTE MAXIMUM RATINGS*
*COMMENT
Temperature Under Bias.................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
thoselistedintheoperationalsectionsofthisspecification
is not implied. Exposure to absolute maximum rating
conditionsforextendedperiodsmayaffectdevicereliability.
Voltage on any Pin with Respect to V ......... –1V to +7V
SS
D.C. Output Current ............................................. 5mA
Lead Temperature
(Soldering, 10 Seconds) ............................. 300°C
RECOMMENDED OPERATING CONDITIONS
Supply Voltage
X25F064/032/016/008
X25F064/032/016/008–5
Limits
Temp
Min.
0°C
Max.
+70°C
+85°C
1.8V to 3.6V
4.5V to 5.5V
Commercial
Extended
Industrial
–20°C
–40°C
6685 PGM T07.3
+85°C
6685 PGM T06.2
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Limits
Symbol
Parameter
Min.
Max.
Units
Test Conditions
SCK = V x 0.1/V x 0.9 @ 1MHz,
I
V
Supply Current (Active)
5
mA
CC
CC
CC CC
SO = Open, CS = V
SS
(2)
I
I
I
I
V
V
Supply Current (Standby)
Supply Current (Standby)
1
µA
µA
µA
µA
V
CS = V , V = V or V , V
= 3.6V
= 5V
SB1
SB2
LI
CC
CC IN SS CC CC
10
10
10
CS = V , V = V or V , V
SS
CC IN CC CC
CC
Input Leakage Current
Output Leakage Current
Input LOW Voltage
V
V
= V
to V
IN
SS
= V
CC
to V
–1
LO
OUT
SS
CC
(1)
V
V
V
V
V
V
V
x 0.7
V
x 0.3
IL
CC
CC
(1)
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
V
+ 0.5
V
IH
CC
0.4
0.4
V
I
I
I
I
= 1.5mA, V
= 2.7V
= 2.7V
= 5V
OL1
OH1
OL2
OH2
OL
OH
OL
OH
CC
V
V
– 0.3
– 0.8
V
= –0.4mA, V
CC
= 3mA, V
CC
= –1.6mA, V = 5V
CC
CC
CC
V
V
6685 PGM T08.4
POWER-UP TIMING
Symbol
Parameter
Min.
Max.
Units
(3)
t
Power-up to Read Operation
1
ms
PUR
(3)
t
Power-up to Write Operation
5
ms
PUW
6685 PGM T09
CAPACITANCE T = 25°C, f = 1MHz, V
= 5V.
A
CC
Symbol
Test
Output Capacitance (SO)
Input Capacitance (SCK, SI, CS, WP, HOLD)
Max.
Units
Conditions
= 0V
(2)
C
C
8
6
pF
pF
V
OUT
OUT
(2)
IN
V
IN
= 0V
6685 PGM T10.1
Notes: (1) VIL min. and VIH max. are for reference only and are not tested.
(2) This parameter is periodically sampled and not 100% tested.
(3) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
8