欢迎访问ic37.com |
会员登录 免费注册
发布采购

X4285S8 参数 Datasheet PDF下载

X4285S8图片预览
型号: X4285S8
PDF下载: 下载PDF文件 查看货源
内容描述: CPU监控器, 128K EEPROM [CPU Supervisor with 128K EEPROM]
分类和应用: 光电二极管监控可编程只读存储器电动程控只读存储器电可擦编程只读存储器
文件页数/大小: 22 页 / 405 K
品牌: XICOR [ XICOR INC. ]
 浏览型号X4285S8的Datasheet PDF文件第6页浏览型号X4285S8的Datasheet PDF文件第7页浏览型号X4285S8的Datasheet PDF文件第8页浏览型号X4285S8的Datasheet PDF文件第9页浏览型号X4285S8的Datasheet PDF文件第11页浏览型号X4285S8的Datasheet PDF文件第12页浏览型号X4285S8的Datasheet PDF文件第13页浏览型号X4285S8的Datasheet PDF文件第14页  
X4283/85 – Preliminary Information
Figure 10. Writing 12 bytes to a 64-byte page starting at location 60.
8 Bytes
Address Pointer
Ends Here
Addr =
8
4 Bytes
Address
=7
Address
60
Address
n-1
The master terminates the Data Byte loading by issuing
a stop condition, which causes the device to begin the
nonvolatile write cycle. As with the byte write operation,
all inputs are disabled until completion of the internal
write cycle. See Figure 9 for the address, acknowledge,
and data transfer sequence.
Stops and Write Modes
Stop conditions that terminate write operations must be
sent by the master after sending at least 1 full data byte
plus the subsequent ACK signal. If a stop is issued in
the middle of a data byte, or before 1 full data byte plus
its associated ACK is sent, then the device will reset
itself without performing the write. The contents of the
array will not be effected.
Acknowledge Polling
The disabling of the inputs during nonvolatile cycles
can be used to take advantage of the typical 5ms write
cycle time. Once the stop condition is issued to indicate
the end of the master’s byte load operation, the device
initiates the internal nonvolatile cycle. Acknowledge
polling can be initiated immediately. To do this, the
master issues a start condition followed by the Slave
Address Byte for a write or read operation. If the device
is still busy with the nonvolatile cycle then no ACK will
be returned. If the device has completed the write oper-
ation, an ACK will be returned and the host can then
proceed with the read or write operation. Refer to the
flow chart in Figure 11.
Figure 11. Acknowledge Polling Sequence
Byte Load Completed
by Issuing STOP.
Enter ACK Polling
Issue START
Issue Slave Address
Byte (Read or Write)
Issue STOP
ACK
returned?
YES
NO
Nonvolatile Cycle
Complete. Continue
Command Sequence?
NO
Issue STOP
YES
Continue Normal
Read or Write
Command Sequence
PROCEED
REV 1.17 11/27/00
www.xicor.com
Characteristics subject to change without notice.
10 of 22