X9312
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Military
Min.
0°C
–40°C
–55°C
Max.
+70°C
+85°C
+125°C
3865 PGM T03.1
Supply Voltage
X9312
Limits
5V
±10%
3865 PGM T04.1
D.C. OPERATING CHARACTERISTICS
(Over recommended operating conditions unless otherwise specified.)
Limits
Symbol
I
CC
I
SB
I
LI
V
IH
V
IL
R
W
V
VH
V
VL
C
IN(5)
Parameter
V
CC
Active Current
Standby Supply Current
CS, INC,
U/D Input
Leakage Current
CS, INC,
U/D Input
HIGH Voltage
CS, INC,
U/D Input
LOW Voltage
Wiper Resistence
VH Terminal Voltage
VL Terminal Voltage
CS, INC,
U/D Input
Capacitance
Min.
Typ.
(4)
1
500
Max.
3
1000
±10
2
–1
40
0
0
V
CC
+ 1
0.8
100
15
15
10
Units
mA
µA
µA
V
V
Ω
V
V
pF
Max. Wiper Current
±1mA
Test Conditions
CS
= V
IL
, U/D = V
IL
or V
IH
and
INC
= 0.4V/2.4V @ max. t
CYC
CS
= V
CC
– 0.3V, U/D and
INC
=
V
SS
or V
CC
– 0.3V
V
IN
= V
SS
to V
CC
V
CC
= 5V, V
IN
= V
SS
,
T
A
= 25°C, f = 1MHz
3865 PGM T05.3
STANDARD PARTS
Part Number
X9312Z
X9312W
X9312U
X9312T
Maximum Resistance
1KΩ
10KΩ
50KΩ
100KΩ
Wiper Increments
10.1Ω
101Ω
505Ω
1010Ω
Minimum Resistance
40Ω
40Ω
40Ω
40Ω
3865 PGM T08.1
Notes:
(4) Typical values are for T
A
= 25°C and nominal supply voltage.
(5) This parameter is periodically sampled and not 100% tested.
5