欢迎访问ic37.com |
会员登录 免费注册
发布采购

AEH24US30 参数 Datasheet PDF下载

AEH24US30图片预览
型号: AEH24US30
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 2 页 / 87 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号AEH24US30的Datasheet PDF文件第2页  
AC-DC
15-24 Watts
AEH Series
xppower.com
Output Voltages from 3- 48 VDC Available
Non-Standard Outputs
Universal Input
+70 ºC Operating Temperature
High Efficiency - Up to 85%
Class 1 Earthing
Non-standard Connectors Available
Specification
Input
• 90-264 VAC
• 47-63 Hz
• 0.4 A for AEH15, at 230 VAC
0.7 A for AEH24, at 230 VAC
Inrush Current
• 15/30 A max at 115/230 VAC 100% load,
cold start
Earth Leakage Current
• <0.5 mA max at 115 VAC/60Hz
<0.75 mA max at 230 VAC/50Hz
Input Voltage
Input Frequency
Input Current
General
Efficiency
Isolation
• Up to 85%
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 100 kHrs per MIL-HDBK-217F
MTBF
Environmental
Operating Temperature
• 0 ˚C to +70 ˚C, derate linearly from
full load at +40 ˚C to half load at +70 ˚C
Operating Humidity
• 5-95 % RH, non-condensing
Storage Temperature
• -40 ˚C to +85 ˚C
Vibration
• 2 g on 3 axes
Output
Output Voltage
• See tables (factory set). Non-standard
voltages available - contact sales
Initial Set Accuracy
• 5%
Start Up Delay
• 2 s max
Hold Up Time
• 20 ms min at full load and 115 VAC
Line Regulation
• See tables
Load Regulation
• See tables
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 2% pk-pk, 20 MHz BW
Overvoltage Protection
• 112-132% Vnom, auto reset
Overload Protection
• 112-132% of nominal, auto recovery
Temperature
• ±0.04% /˚C max
Coefficient
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
EN55022 level B, conducted and radiated
EN61000-3-2, Class A
EN61000-3-3
EN61000-4-2, level 2 Perf Criteria A
EN61000-4-3, level 3 Perf Criteria A
EN61000-4-4, level 2 Perf Criteria A
EN61000-4-5, level 3 Perf Criteria A
EN61000-4-6, level 2 Perf Criteria A
EN61000-4-11 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950, UL60950,
CSA C22.2 No. 950 per cUL,
UL60950
Safety Approvals