欢迎访问ic37.com |
会员登录 免费注册
发布采购

AEH45UM32 参数 Datasheet PDF下载

AEH45UM32图片预览
型号: AEH45UM32
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 4 页 / 377 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号AEH45UM32的Datasheet PDF文件第2页浏览型号AEH45UM32的Datasheet PDF文件第3页浏览型号AEH45UM32的Datasheet PDF文件第4页  
AC-DC
45-130 Watts
AEH Series
xppower.com
Output Voltages from 2.5 V to 48 V
Non-standard Outputs Available
Universal Input
Single & Multiple Output Versions
0 °C to +70 °C Operating Temperature
Efficiency up to 80%
Non-standard Connectors Available
Specification
Input
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• 1.5/0.7 A for AEH45, at 115/230 VAC
1.9/1.5 A for AEH80, at 115/230 VAC
3.2/1.7 A for AEH130, at 115/230 VAC
Inrush Current
• AEH45 & 80: 30 A max at 230 VAC
AEH130: 60 A max at 230 VAC
cold start
Power Factor
• EN61000-3-2 class A
Earth Leakage Current
• <0.5 mA max at 115 VAC/60 Hz
<0.75 mA max at 230 VAC/50 Hz
General
Efficiency
Isolation
• Up to 80%
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 67-83 kHz for AEH45
58 kHz typical for AEH80
53-76 kHz for AEH130
• 100 kHrs per MIL-HDBK-217F
Switching Frequency
MTBF
Environmental
Operating Temperature
• 0 °C to +70 °C, derate linearly from 100%
load at +40 °C to 50% load at +70 °C
Operating Humidity
• 5-95% RH, non-condensing
Storage Temperature
• -40 °C to +85 °C
Vibration
• 2 g on 3 axes
Output
Output Voltage
• See tables. Factory set non-standard
voltages available - contact sales
Initial Set Accuracy
• 5%
Start Up Delay
• 2 s max
Hold Up Time
• 16 ms min (>50 ms AEH130)
Line Regulation
• See note 2
Load Regulation
• See note 2
Transient Response
• 4% max deviation, recovery to within
1% in 4 ms for a 50% load change
Ripple & Noise
• 2% pk-pk for outputs
≤3.3
V
1% pk-pk for all other outputs
20 MHz BW
Overvoltage Protection
• 112-132% Vnom, auto reset
Overload Protection
• Output 1 only 110-150% of nominal
Temperature
• ±0.04%/°C max
Coefficient
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
EN55022 level B, conducted and radiated
EN61000-3-2, Class A
EN61000-3-2
EN61000-4-2, level 2 Perf Criteria A
EN61000-4-3, level 3 Perf Criteria A
EN61000-4-4, level 2 Perf Criteria A
EN61000-4-5, level 3 Perf Criteria A
EN61000-4-6, level 2 Perf Criteria A
EN61000-4-11 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950-1, UL60950-1,
CSA C22.2 No. 950 per cUL, CE Mark
Safety Approvals