欢迎访问ic37.com |
会员登录 免费注册
发布采购

AMM120PS36 参数 Datasheet PDF下载

AMM120PS36图片预览
型号: AMM120PS36
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 2 页 / 71 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号AMM120PS36的Datasheet PDF文件第2页  
AC-DC
120 Watts
AMM120 Series
Energy Star Level V
24 V
xppower.com
CEC 2008 & EISA 2007 Compliant
Worldwide Medical Approvals
Small Size/High Power Density
Class I and Class II Versions
Operating Temperature up to +60 °C
Locking Output Connector
Specification
Input
• 90-264 VAC
• 47-63 Hz
• 1.6 A rms at 115 VAC,
0.8 A rms at 230 VAC
Inrush Current
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Power Factor
• 0.98 typical
Earth Leakage Current
• 90 µA max at 115 VAC/60 Hz,
(Class I Versions)
150 µA max at 230 VAC/50 Hz
Input Protection
• Internal 3 A fuse in live and neutral lines
Input Voltage
Input Frequency
Input Current
General
Efficiency
Isolation
• 85% typical
• 4000 VAC Input to Output
1500 VAC Input to Ground (Class I only)
500 VAC Output to Ground (Class I only)
• 40-120 kHz variable
• 3.7 W/In
3
• >175 kHrs per MIL-HDBK-217F
Switching Frequency
Power Density
MTBF
Environmental
Operating Temperature
• 0 °C to +60 °C, derate from 100% power
at +40 °C to 50% power at +60 °C
Cooling
• Convection-cooled
Operating Humidity
• 10-95% RH, non-condensing
Storage Temperature
• -20 °C to +80 °C
Operating Altitude
• 3000 m
Shock
• 30 g, 10 ms on 3 axes
Vibration
• 5-100 Hz, 2.31 m/s
2
, 20 mins, 3 axes
Output
12 to 48 VDC
Not user-adjustable
±2 %
No minimum load required
2 s max at 115 VAC
<80 ms at 115 VAC
15 ms minimum at full load & 115 VAC
0.5% maximum
Total regulation <±5%
4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 2% max pk-pk (see note 1)
Overvoltage Protection
• 110-140% Vnom, recycle input to reset
Overtemperature
• Unit shuts down, recycle input to reset
Protection
Overload Protection
• 110-150%, auto recovery
Short Circuit Protection
• Trip and restart (Hiccup mode)
Temperature
• 0.04%/°C
Coefficient
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
• EN55011/FCC/VCCI, Class B conducted
EN55011/FCC/VCCI, Class B radiated
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
• EN61000-4-11, 70% U
T
for 10 ms,
40% U
T
for 100 ms, <5% U
T
for 5000 ms
Perf Criteria A, B, B (Perf Criteria A, A, B
with 70% load)
• EN60601-1, UL60601-1, CSA22.2 No.
601-1 per cUL, CE Mark
Safety Approvals