欢迎访问ic37.com |
会员登录 免费注册
发布采购

AMM150PS48 参数 Datasheet PDF下载

AMM150PS48图片预览
型号: AMM150PS48
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 2 页 / 89 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号AMM150PS48的Datasheet PDF文件第2页  
AC-DC
150 Watts
AMM150 Series
Energy Star Level V
≥15
V
xppower.com
CEC 2008 & EISA2007 Compliant
Worldwide Medical Approvals
Class I and Class II Versions
Optional AC Cable Restraint
Optional Output Connectors
Low Leakage Current
Specification
Input
• 90-264 VAC
• 47-63 Hz
• 2 A rms at 115 VAC,
1 A rms at 230 VAC
Earth Leakage Current
• 90 µA max at 115 VAC/60 Hz,
(Class I Versions)
150 µA max at 230 VAC/50 Hz
Input Protection
• Internal 3 A fuse in live and neutral lines
No Load Input Power
• <0.5 W
Input Voltage
Input Frequency
Input Current
General
Efficiency
Isolation
• 85% minimum (see note 4)
• 4000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 50-110 kHz
• 2.9 W/Inch
3
• 150 kHrs per MIL-HDBK-217F
Switching Frequency
Power Density
MTBF
Environmental
Operating Temperature
• 0 ºC to +60 ºC, derate linearly from
100% load at +40 °C to 50% at +60 °C
Cooling
• Natural convection
Operating Humidity
• 5-95% RH, non-condensing
Storage Temperature
• -40 ºC to +85 ºC
Operating Altitude
• 3000 m
Shock
• 30 g, 10 ms on 3 axes
Vibration
• 5-100 Hz, 2.31 m/s
2
, 20 mins on 3 axes
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
See table
±2%
No minimum load required
2 s max at 115 VAC
<80 ms at 115 VAC
15 ms at 110 VAC
±0.5%
±5%
4% deviation recovering to <1% within
300 µs for 25% step change
Ripple & Noise
• 2% pk-pk max, see note 1
Overvoltage Protection
• 112-140% of nominal output voltage,
auto recovery
Overtemperature
• Unit shuts down, auto recovery
Protection
Overload Protection
• 130-180% auto recovery
Short Circuit Protection
• Trip & restart (hiccup mode)
Temperature
• ±0.04%/°C
Coefficient
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
• EN55011, Class B conducted
EN55011, Class B radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, ±8 kV air & ±6 kV indirect
Discharge, Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V rms Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
• EN61000-4-11, >95% U
T
for 10 ms,
60% U
T
for 100 ms, 30% U
T
for 500 ms
Perf Criteria A, B, B
• EN60601-1, UL60601-1, CSA22.2
No. 601-1 per cUL
Safety Approvals