AC-DC
Models and Ratings
Output Voltage
12 V
24 V
48 V
12 V
24 V
48 V
24 V
48 V
24 V
48 V
24 V
48 V
Notes
Output Voltage Trim
11.4-14.5 V
22.5-30.0 V
45.0-55.0 V
11.4-14.5 V
22.5-30.0 V
45.0-55.0 V
22.5-28.5 V
47.0-56.0 V
22.5-28.5 V
47.0-56.0 V
22.5-28.5 V
47.0-56.0 V
Output Current
10.0 A
5.0 A
2.5 A
10.0 A
5.0 A
2.5 A
10.0 A
5.0 A
20.0 A
10.0 A
20.0 A
10.0 A
DNR120-480
Typical Efficiency
84%
86%
87%
84%
86%
87%
89%
90%
89%
90%
88%
89%
Model Number
DNR120LS12
(1,2,3)
DNR120LS24
(1,2,3)
DNR120LS48
(1,2,3)
DNR120AS12-I
(3,4)
DNR120AS24-I
(3,4)
DNR120AS48-I
(3,4)
DNR240PS24-I
(3,4)
DNR240PS48-I
(3,4)
DNR480PS24-I
(3,4)
DNR480PS48-I
(3,4)
DNR480TS24-I
DNR480TS48-I
1. Add suffix ‘-I’ to DNR120LS model number for parallel function, (120AS, 240 & 480 W models have parallel function as standard). A maximum of 3 units can be
paralleled. Total power available is 90% of the rated current of each unit.
2. For PFC version of DNR120LS, replace ‘L’ in the model number with ‘P’ e.g. DNR120LS24 becomes DNR120PS24 (Typical power factor 0.7).
3. Add suffix ‘-D’ for detachable connector option.
4. For DC standby, remove ‘-I’ and add # to the end of the model number.
Available from Farnell. See pages 204-206.
Derating Curves
DNR120-240
DNR120 & 240
DNR120 & 240
100
80
Load (%)
DNR480PS
DNR480PS
DNR480PS
100
80
Load (%)
DNR480TS
DNR480PS
100
80
Load (%)
Load (%)
DNR120 & 240
100
80
DNR480TS
DNR480TS
100
80
Load (%)
DNR480TS
100
80
100
80
Load (%)
100
80
60
40
20
0
-10
10
40
20
0
-10
10
40
20
0
30
10
-10
Load (%)
60
Load (%)
60
60
40
20
0
60
40
20
0
-25
-10
-20
0
60
40
20
0
60
40
20
60
40
20
0
-25
-10
-20
0
0
0
20
20
40
0
30
10
50
40
20
60
50
30
70
60
40
70
50
60
70
-25 -20
-10
10
40
0
20
-20
30
-10
20
-25
10
40
50
60
0
30
10
60
20
70
30
50
40
70
50
60
0
70
-25 -20
20
0
20
-20
30
-10
40
-25
10
40
50
60
50
0
30
10
60
20
70
30
40
70
50
60
Ambient Temp (˚C)
Ambient Temp (˚C)
Ambient Temp (˚C)
Ambient Temp (˚C)
Ambient Temp (˚C)
Ambient Temp (˚C)
Ambient Temp (˚C)
Ambient Temp (˚C)
Ambient Temp (˚C)
Standby Versions
+
+
DC OK
DC OK
DC LO
ON
K1
6
1
Output Set Voltages For Standby Versions
Model
DNR120AS12#
D1
K1
Fuse
LOAD
Voltage
13.6 V
27.2 V
54.5 V
27.2 V
54.5 V
27.2 V
54.5 V
Current
8.8 A
4.4 A
2.2 A
8.8 A
4.4 A
17.6 A
8.8 A
DC OK
Shutoff
10.8 V ±5%
21.6 V ±5%
43.2 V ±5%
21.6 V ±5%
43.2 V ±5%
21.6 V ±5%
43.2 V ±5%
DNR120AS24#
DNR120AS48#
DNR240PS24#
R
L
> 700ohm
DCOK
-
Battery
22K
DCOK
0.5W
DNR240PS48#
DNR480PS24#
DNR480PS48#
1
3
-Vout
5.1K
0.3W
Maximum current drain from battery by PSU when inactive 22 mA.
-Vout
a) Relay Example
b) 5 V Signal Example
-
DC OK
Volt free contact closed when
good voltage from PSU or battery
available to the load in standby system
Available on 24 V models only.
DCOK
Open = Output fail
Closed = Output good
DCOK
Contact Rating: 0.3 A at 60 VDC