欢迎访问ic37.com |
会员登录 免费注册
发布采购

ECM40US15 参数 Datasheet PDF下载

ECM40US15图片预览
型号: ECM40US15
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 4 页 / 176 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号ECM40US15的Datasheet PDF文件第2页浏览型号ECM40US15的Datasheet PDF文件第3页浏览型号ECM40US15的Datasheet PDF文件第4页  
AC-DC
40-100 Watts
ECM Series
xppower.com
Compact Size - High Power Density
Industrial & Medical Approvals
Low Leakage Current
Level B Conducted Emissions
EN61000-3-2, -3 Compliant
Convection-cooled
Class II Approved 40-60 W Models
Specification
Input
• 90-264 VAC (120-370 VDC)
• 47-63 Hz; 440 Hz
• 40 W: 0.4 A max at 230 VAC
60 W: 0.6 A max at 230 VAC
100 W: 0.9 A max at 230 VAC
Inrush
Current
• 40 A max at 230 VAC
Earth Leakage Current
• <125 µA at 115 VAC/60 Hz
<210 µA at 230 VAC/50 Hz
Input Protection
• Internal 3.15 A fuse in line and neutral
Input Voltage
Input Frequency
Input Current
General
Efficiency
Isolation
• 80-85% depending on model
• 4000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 70 kHz typical
• 60 W: 6.25 W/In
3
100 W: 7.40 W/In
3
• 250 kHrs per MIL-HDBK-217F
Switching Frequency
Power Density
MTBF
Environmental
Operating Temperature
• 0 °C to +70 °C. Refer to derating curves
for specific operating limitations.
Cooling
• Convection & fan-cooled ratings
(see derating curves)
Operating Humidity
• 95% RH, non-condensing
Storage Temperature
• -20 °C to +85 °C
Operating Altitude
• 3000 m
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 kHz, 3 axes
Output
Output Voltage
Output Voltage Trim
• See tables
• ±5% on 3.3 V & 5 V versions, ±10% on
other single output models and V1 of
multi-output models. See note 1 for
ECM40/60 models
Initial Set Accuracy
• ±1.0% V1, ±5% V2, V3 & V4
Minimum Load
• See tables
Start Up Delay
• 2 s max
Start Up Rise Time
• 50 ms
Hold Up Time
• 16/75 ms min at 115/230 VAC
Line Regulation
• ±0.5%
Load Regulation
• ±1% single output models;
±3% V1, ±5% V2 & V3 ECM40/60
multi-output models.
±1% V1 & V2, ±5% V3 & V4 ECM100
Cross Regulation
• 2% on ECM40/60 only
Over/Undershoot
• None at turn on/off
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 1% pk-pk, 20 MHz bandwidth
Overvoltage Protection
• 115-135% Vnom, recycle input to reset
Overload Protection
• 110-150% on primary power limit,
auto recovery
Short Circuit Protection
• Trip and restart (Hiccup mode)
Temperature
• 0.05%/°C
Coefficient
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
• EN60601-1-2, EN61204-3, FCC 20780,
EN55022 & EN55011, level B conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, 10 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950, UL60950, CSA 22.2 601.1,
EN60601-1, UL60601-1,
CCC pending, contact sales
Safety Approvals