欢迎访问ic37.com |
会员登录 免费注册
发布采购

HUL200-14 参数 Datasheet PDF下载

HUL200-14图片预览
型号: HUL200-14
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 4 页 / 322 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号HUL200-14的Datasheet PDF文件第2页浏览型号HUL200-14的Datasheet PDF文件第3页浏览型号HUL200-14的Datasheet PDF文件第4页  
AC-DC
175-300 Watts
HUL Series
Compact Size, Low Profile
xppower.com
Up to 5.85 W/in
3
Power Density
Single & Multiple Outputs
Convection-cooled Ratings
Remote On/Off
Power Fail Detect
12 V Fan Supply
Specification
Input
Input Voltage
Input Frequency
Input Current
• 90-132 VAC, 180-264 VAC (auto-ranging)
• 47-63 Hz
• HUL175: 4.4 A max at 115 VAC,
2.2 A max at 230 VAC
HUL200: 5.0 A max at 115 VAC,
2.5 A max at 230 VAC
HUL300: 6.3 A max at 115 VAC,
3.15 A max at 230 VAC
Inrush Current
• 35 A at 115 VAC, 70 A max at 264 VAC
+25 °C cold start
Power Factor
• Passive PFC, meets EN6100-3-2, -3
Earth Leakage Current
• <1.5 mA at 230 VAC / 50 Hz
General
Efficiency
Isolation
• 80% typical
• 3000 VAC Input to Output,
1500 VAC Input to Ground,
500 VAC Output to Ground
• 42 kHz typical
• HUL175: 4.51 W/In
3
, HUL200: 5.85 W/In
3
,
HUL300: 4.41 W/In
3
• On = Logic high 100-500 ms after outputs
with regulation
Fail = Logic low at least 1 ms prior to loss
of output
• 100 kHrs per MIL-HDBK-217F
Switching Frequency
Power Density
Power Fail Detect
MTBF
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
• See tables
• ±5% on output 1
• ±1% max for single/main output
±5% for auxiliary outputs
Minimum Load
• See tables & note 1 for 175 W model
Start Up Delay
• 1 s max
Start Up Rise Time
• 20 ms max
Hold Up Time
• >15 ms at 115 VAC
Total Regulation
• ±1% max for single output models,
±5% max for multiple output models
Over/Undershoot
• <5% max
Transient Response
• 5% max deviation, recovery to within
1% in 500 µs for a 50% load change
Ripple & Noise
• 1% pk-pk (50 mV max for 3.3 V output)
Overvoltage Protection
• 130% on output 1 only, recycle input to
reset
Overtemperature
• Shuts down when ambient temperature
Protection
exceeds +85 °C, auto recovery
Overload Protection
• 110-135% of total power, auto recovery
Short Circuit Protection
• Trip and restart (Hiccup mode)
Temperature
• ±0.1%/°C
Coefficient
Remote Sense
• HUL175 only. Compensates for 0.5 V drop
on 3.3 V output
Remote On/Off
• On = Logic High or Open
Off = Logic Low or Short
Not available on HUL175
• 12 V, 300 mA
Environmental
Operating Temperature
• 0 °C to +60 °C, derate linearly from 100%
at +40 °C to 50% at +60 °C
Cooling
• See notes
Operating Humidity
• 5-90% RH, non-condensing
Storage Temperature
• -20 °C to +85 °C
Operating Altitude
• 3000 m
Shock
• 15 g (non-operation), 11 ms (half sine
wave), 3 times for each axis
Vibration
• 10-55 Hz (non-operation) 2 g, sweep time
3 mins, 60 mins/axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
• EN55022 and FCC, level B
(level A - 300 W) conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 4 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria A
• EN61000-4-11, 30% 10 ms,
70% 100 ms, 95% 5000 ms,
Perf Criteria A, B, B
• EN60950, UL60950, CSA22.2 No. 950
per cUL, CE Mark
Safety Approvals
Fan Output