欢迎访问ic37.com |
会员登录 免费注册
发布采购

JCL3024S12 参数 Datasheet PDF下载

JCL3024S12图片预览
型号: JCL3024S12
PDF下载: 下载PDF文件 查看货源
内容描述: 直流 - 直流电源 [DC-DC Power Supplies]
分类和应用:
文件页数/大小: 2 页 / 70 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号JCL3024S12的Datasheet PDF文件第2页  
DC-DC
30 Watts
JCL30 Series
2:1 Input Range
High Efficiency up to 91%
xppower.com
-40 °C to +100 °C Operating Temperature
Fixed 270 kHz Switching Frequency
Regulated Single & Dual Outputs
Continuous Short Circuit Protection
Standard Remote On/Off
Specification
Input
Input Voltage Range
• 12 VDC (9-18 VDC)
24 VDC (18-36 VDC)
48 VDC (36-75 VDC)
• See table
• Pi network
• Turn on >71% nominal input,
Turn off <63% nominal input
• 12 V models 25 VDC for 100 ms
24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
General
Efficiency
Isolation Voltage
• See table
• 1500 VDC Input to Output
1000 VDC Input to Case
1000 VDC Output to Case
• 1200 pF typical
• 270 kHz typical
• 1 MHrs to MIL-STD-217F
Input Current
Input Filter
Undervoltage Lockout
Input Surge
Isolation Capacitance
Switching Frequency
MTBF
Environmental
Operating Temperature
Case Temperature
Storage Temperature
Cooling
Operating Humidity
Shock
Vibration
-40 °C to +100 °C (see derating curve)
+100 °C max
-40 °C to +125 °C
Convection-cooled
Up to 90%, non-condensing
30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
• 5-500 Hz, 3 g, for 10 mins on each
of 3 axes
Output
Output Voltage
Output Voltage Adj
Minimum Load
Line Regulation
Load Regulation
Setpoint Accuracy
Cross Regulation
Ripple & Noise
Transient Response
See table
±10% via trim pin
No minimum load required
±0.5% max
±0.5% max from 10% to full load
±1.0% max
±5.0%, see note 2
75 mV pk-pk max, see note 3
3% max deviation, recovery to within
1% in 200 µs for a 25% load change
• 0.02%/°C
EMC
Emissions
• EN55022, Level A conducted & radiated
with external components -
see application note
• EN61000-4-2, Level 2 Perf Criteria B
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, Level 3 Perf Criteria A*
• EN61000-4-5, Level 3 Perf Criteria A*
• EN61000-4-6, 3 V rms Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
Temperature
Coefficient
Overvoltage Protection
• 3.3 V models 3.9 V typical,
5.0 V models 6.2 V typical,
12.0 V models 15.0 V typical,
15.0 V models 18.0 V typical,
±12.0 V models ±15.0 V typical,
±15.0 V models ±18.0 V typical
Overcurrent Protection
• 120% typical
Short Circuit Protection
• Trip & restart (hiccup mode)
Remote On/Off
• ON >2.5 VDC or open circuit
OFF <0.8 VDC or short circuit pin 2 & 3
Thermal Protection
• Shuts down when case measures
+110 °C typical
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
*See note 4