欢迎访问ic37.com |
会员登录 免费注册
发布采购

JPM80PS24 参数 Datasheet PDF下载

JPM80PS24图片预览
型号: JPM80PS24
PDF下载: 下载PDF文件 查看货源
内容描述: 直流 - 直流电源 [DC-DC Power Supplies]
分类和应用:
文件页数/大小: 4 页 / 421 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号JPM80PS24的Datasheet PDF文件第2页浏览型号JPM80PS24的Datasheet PDF文件第3页浏览型号JPM80PS24的Datasheet PDF文件第4页  
AC-DC
80-160 Watts
JPM Series
Low Cost
High Reliability
Power Factor Corrected
xppower.com
Suitable for Battery-charging Applications
Low Ripple & Noise
125% Rating at 230 VAC
Optional Remote On/Off
Specification
Input
Input Voltage
Input Frequency
Input Current
• 85-264 VAC (120-370 VDC)
• 47-63 Hz
• JPM80: 0.7 A max at 230 VAC
JPM120: 1.1 A max at 230 VAC
JPM160: 1.4 A max at 230 VAC
Inrush Current
• 40 A at 230 VAC cold start
Power Factor
• >0.9
Earth Leakage Current
• <2 mA at 230 VAC
General
Efficiency
Isolation
• See tables
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• >183 kHrs per MIL-HDBK-217F (+25 °C)
MTBF
Environmental
Operating Temperature
• -10 °C to +60 °C, see derating curves
Cooling
• JPM80 & JPM120 convection-cooled,
JPM160 includes internal fan
Operating Humidity
• 20-90% RH, non-condensing
Storage Temperature
• -20 °C to +85 °C
Vibration
• 2 g, 10-500 Hz, 10 min/cycle for 60
minutes each axis
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage Protection
Overtemperature
Protection
Overload Protection
Temperature
Coefficient
Remote On/Off
See tables
+10%, -5%
±2%
600 ms max
30 ms max
25 ms min
±0.5%
See tables
See tables
110-135% Vnom, recycle input to reset
Shuts down at +95 °C ±5 °C (measured
internally) with auto recovery, only on
JPM120 & JPM160
• 105-150% constant current, auto recovery
• ±0.05%/°C
• 4-10 VDC On, <0.8 VDC Off, optional.
Add suffix ‘R’ to model number
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
• EN55022 (CISPR22), level B conducted
EN55022 (CISPR22), level B radiated
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
EN61000-4-11, 30% 10 ms,
60% 100 ms, >95% 5000 ms,
Perf Criteria A, B, B
• EN60950-1-1:2001, UL60950-1,
CSA22.2 No. 60950-1, CE Mark LVD
Safety Approvals